Dorma ES 200 Manual - Página 3
Procurar online ou descarregar pdf Manual para Abertura de porta de garagem Dorma ES 200. Dorma ES 200 10 páginas. Sliding door operator
Também para Dorma ES 200: Manual (12 páginas), Manual de início rápido (4 páginas)

Door parameters
1-panel sliding door
– Clear passage width LW
– Door panel weight, max.
2-panel sliding door
– Clear passage width LW
– Door panel weight, max.
Technical data
Height
Overall depth
Opening and closing force, max. 150 N
Opening speed
(incremental setting)
Closing speed
(incremental setting)
Hold-open time
Mains voltage, frequency
Power consumption
Class of protection
Compliant with
EU low-voltage directives
Manufacture according to
ISO 9001:2000
Servicing and commissioning
can be performed quickly
and easily via an integrated
display with pushbuttons on
the front panel of the con-
trol unit or with a hand-held
computer (PALM) and the
DORMA Automatic Service
Program (ASP).
ES 200
Basic module (BM)
Modular design
700 – 3000 mm
Microprocessor-controlled function programs
1 x 200 kg
– Off
– Automatic
800 – 3000 mm
– Permanent open
2 x 160 kg
– Partial opening
– Exit only
– Night-bank control
Connections for
– electro-mechanical lock
100 and 150 mm
– light barriers
180 mm
Adjustment of all basic parameters
x
via integrated display and pushbuttons
PALM parameter setting
10 – 70 cm/s
24 V output for external loads
Read-out error memory with error codes
10 – 50 cm/s
DCW bus interface
0 – 180 sec.
Rechargeable battery pack for emergency operation
230 V, 50/60 Hz
250 W
IP 20
Function module (FM) – optional extra
Pharmacy control
x
Door status detection (triple-mode)
Main and secondary closing edge protection
x
Emergency closing
Bell contact
Airlock control
Synchronising mode
Additional equipment
Electro-mechanical lock (bistable)
Manual release of electro-mechanical lock
Light barriers
Backup battery pack
(emergency opening, emergency closing)
Module for coupling to EIB or
LON building control systems*
* Please ask your Sales Consultant for series start date.
x standard
X optional
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
X
X
X
X
X
3