V - TROUBLESHOOTING AND SOLUTIONS
Before any intervention, check oil level and air supply pressure (between 5.5 and 7 bar)
PROBLEM
Damaged mandrel threads.
Di cult screwing/unscrewing
actions.
RIVKLE
threads
®
defective after installation.
RIVKLE
turns in the hole.
®
Device does not unscrew
at end of crimping stroke.
Screwing function inoperative.
No crimping stroke.
Tool mandrel spins continuously.
Unscrewing function inoperative
(device blocked on the part).
Tool stuck in the RIVKLE
.
®
Visa, Mastercard, Discover & AMEX Accepted
8
PROBABLE CAUSE
1 - Thickness to be crimped
incompatible with RIVKLE
2 - Excessive crimping stroke.
3 - Device positioning incorrect
during crimping.
4 - Damaged pull-out rod threads.
1 - Damaged mandrel threads.
2 - RIVKLE
incompletely screwed
®
on mandrel.
3 - Excessive crimping stroke.
4 - Thickness to be crimped
incompatible with RIVKLE
1 - Thickness to be crimped
incompatible with RIVKLE
2 - RIVKLE
head not bearing
®
on anvil at the time of crimping.
3 - Insu cient crimping stroke.
1 - Low compressed air pressure.
2 - Low oil level.
3 - Motor problem.
1 - No air supply to device.
2 - Push-Pull valve out of adjustment.
1 - Adjustment ring at minimum
position.
2 - Low oil level in tool.
1 - Push-Pull valve out of adjustment.
1 - RIVKLE
tapped threads
®
or mandrel threads damaged.
2 - Low oil level.
3 - Insu cient air pressure.
ISO CERTIFIED
.
Fax: 262.252.5033
SOLUTION
1 - Check crimping stroke range
.
in RIVKLE
catalogue.
®
®
2 - Repeat crimping test according
to instructions.
3 - Keep mandrel/tool perpendicular
to parent material.
4 - Replace mandrel as per instructions.
1 - Replace mandrel as per instructions.
2 - Adjust anvil position as per
instructions.
3 - Repeat crimping tests as per
instructions.
.
4 - Check crimping stroke according
®
to RIVKLE
catalogue.
®
1 - Check crimping stroke according
.
to RIVKLE
catalogue.
®
®
2 - Ensure that head is correctly
bearing, when screwing.
3 - Repeat crimping test as per
instructions.
1 - Check air supply pressure.
2 - Fill oil level as per instructions
in § 5.
3 - Check motor rotation at no load.
1 - Check that compressed air
supply to device is ensured.
2 - Adjust Push-Pull valve per
instruction item.
1 - Adjust crimping stroke.
2 - Fill oil level.
1 - Adjust Push-Pull valve per
instruction item.
1 - To release the tool:
- position pin (9) to match an
aperture in nose-piece (5) and
drive pin out,
- unscrew anvil (2),
- release the tool.
2 - Fill oil level as per instructions
in § 5.
3 - Check air pressure.
CALL TODAY
800.236.3200