Specifications

Power Supply and Requirements
 Zodiac FR100
 Supplied Plug-in Transformer: .......................................... 12 VDC, 1A
User Capacity:
 CA-ZODFR100 - 500 Users
Verification Method: .......................................................... Face Recognition
Verification Speed:.......................................Less than 1 Second (500 Users)
Keyboard: ....................................................................... 4x4 Touch Keyboard
LCD: ..... 3.5 " TFT Color Screen, 65000 Bright Color, 320x240 Resolution
Communication Method: ...................Standard TCP/IP, USB Flash Drive
Environment Light: ......................................................................... 0-5000Lux
Working Distance: ........................................................................... 30-80cm
Working Temperature: .................................. 0
Working Humidity: ...................................................................... 20% - 80%
Installation Method: ................................................................... Wall Mount
Capture Distance: ............................................. 30 cm - 80 cm [11.8" - 31.5"]
Communications Cable (multi-reader configuration)
 RJ-45 Cable: .......................................................... Standard RJ-45 cable
On-Board Relay (standalone configuration)
 Normally Open Dry Contact Relay: ................... Rated @ 30 VDC, 1A
Wiegand Output
 Standard 26-bit
 Cansec 37-bit
Reader Cable (required when connected to an access controller)
 Wiegand Cable: ....................... 4 conductor (twisted pair not required)
............................................................................
...............................................................
Dimensions & Weight
 Reader: ............................................ 200 mm (l) x 95 mm (w) x 115 mm
..........................................................
 Weight: .......................................................................... 505 g (1.11 lbs)
Specifications subject to change without notice.
®
Reader: ............................................. 12 VDC, 500 mA
TM
Zodiac FR100
Installation Manual
o
o
C - 40
C [32
22 AWG, overall shield
152 m (500 ft) max total length
[ 7.87" (l) x 3.74" (w) x 4.53" (h) ]
June 2014 • Rev. 1.2
o
o
F - 104
F]
Page 4 of 15