1.3

Cylinder specifications

Standard 1 1/8" mortise cylinder, randomly
keyed supplied by factory. Spacer required
for longer cylinder such as when using an
IC core.
5/16" - 11/32"
(6310D)
21/32"
Cam
1.4

DIP switch setting

DIP switch settings should
be completed at time of initial
installation; check local building
code. Factory settings are as follows:
Standard Factory Setting
ON
OFF
4
1
23
S3
ON
OFF
1
23
4
S1
Exit Device
4
To Change Cylinder: Carefully remove filler from rail. Unscrew cylinder
nut, remove actuator and replace cylinder. Spacer required for cylinders
over 1 1/8". Insert cylinder as shown, re-install actuator & secure with
cylinder nut. Do not over tighten. Re-install filler in rail and reconnect the
small pigtail connectors. Use caution not to pinch or bind wires.
Note: If DIP switch settings are required to be changed, do it now prior to
re-installing filler in rail. (See Section below.)
1 1/8" Standard
DE filler
Underside of filler
95011817 (1135-88) IDE-20
Cylinder nut
4000-167-501
Actuator-DE
95055525
Cylinder
90J10SC118
(1) Audible fire alarm: (On) Active ; (Off) Not active
(2) For future use.
S1
(3) Power up state: (On) Locked ; (Off) Un-locked
(4) Door position switch: (On) In-Active ; (Off) Active
(1) Nuisance alarm time: (See chart below.)
(2) Nuisance alarm time: (See chart below.)
S3
(3) Authorized egress time: (See chart below.)
(4) Authorized egress time: (See chart below.)
Factory
3 Seconds
2 Seconds
ON
OFF
1
2
1
2
ON
OFF
3
4
3
Factory
5 Seconds
15 Seconds
Cylinder specifications
DIP switch settings
Underside of filler
1 Seconds
0 Seconds
1
2
1
2
4
3
4
10 Seconds
20 Seconds
3
4