Quick commissioning and customer-specific configuration of
safe locks
Preparation
1) The local regulations for installation, safety and security must be complied with.
2) Slightly pull out the battery compartment of the input unit and remove the back
plate from the cover. Mount the back plate and the safe lock on the safe.
3) Route the connecting cable through the designated cable feed-through in the
back plate and connect the safe lock to the input unit.
4) Connect the power supply cable of the battery compartment to the input unit.
5) Reassemble the cover of the input unit onto the back plate.
6) Insert the batteries and push the battery compartment into the input unit.
Make sure that the battery compartment operates the micro-switch on the PCB.
7) The input unit starts. If the beep signal does not stop, repeat step #6 above.
Configuration through input unit
1) Open the safe lock (e.g. by entering the factory set Master code 0 0 1 2 3 4 5 6).
2) Make sure that the bolt remains retracted during configuration of the safe lock.
(Please consider the factory setting of 6 seconds for the "Bolt open time". The
lock closes automatically after the "Bolt open time" has elapsed.)
3) Use the Master, Manager or User code to enter the desired programming level.
4) Configure the safe lock according to the customer specifications and write down
the settings. (Note: The lock must be open during configuration.)
5) Leave from the programming mode by pressing the
6) Release the bolt to leave the customer-specific configuration.
Configuration with AS284-USBW / AS284-NETW Axessor Programming Software
1) Connect the admin or operator dongle to the PC and start the AS284-W soft-
ware. (Note: Please contact the local dormakaba support to order the software.)
2) Connect the input unit to the PC via an USB cable with plugs of type A-B.
3) In AS284 Locks overview check the serial number and select the desired safe lock.
4) In menu <Additional/Inputs> set the checkbox to Door contact on Inp.2 (Input 2).
5) Enter a valid code in input unit to open the safe lock: the bolt opens.
6) Click the software button <Apply> of AS284-W within 6 seconds (factory set-
ting) before the "Bolt open time" elapses: the bolt remains retracted.
(Note: Repeat steps 5 and 6 when the bolt closes automatically or the software
AS284-W reports that the lock refused the last reading or writing operation.)
7) Configure the safe lock according to the customer specifications.
8) Check the configuration: select the menu <Main / Audit> and press <Read audit>.
9) Disconnect the input unit from the PC, leave the customer-specific configuration.
Note
For further information on configuration, refer to the Axessor Technical
Manual. The QR code to access the internet download site is on page 2.