Dormakaba ED connection board CAN Manual de instruções de montagem - Página 7

Procurar online ou descarregar pdf Manual de instruções de montagem para Unidade de controlo Dormakaba ED connection board CAN. Dormakaba ED connection board CAN 16 páginas.

Assembly Instruction

4.2 Mounting the ED connection board CAN

Note Structure of the ED connection board CAN [} 3.3].
1.
Set the parameter "C1 -> Configuration of the COM1 interface (vertical plug)"
to "1".
2. Switch off the ED operator on the active door leaf (power switch to "0").
3. Remove the cladding (3) from the active door leaf operator, see "Note the
structure of the ED 100/250 drive [} 4.1]".
4. Pull the ribbon cable (4) out of the standard ED connection board (2), see
"Note the structure of the ED 100/250 drive [} 4.1]".
5. Remove the plug from the board.
6. Press the locking elements inwards in the suggested order and remove the
standard ED connection board (2), see "Note the structure of the ED 100/250
drive [} 4.1]".
7.
Insert the cable ends of the connection cables from the inside to the empty
board slot.
8. Plug the ED connection board CAN over the locking elements.
9. Plug in the plugs and connect the lines.
10. Pull the open cable end of each CAN connection cable out through the middle
opening in the ED connection board CAN.
060636 45532/16923 - 2023-04
2.
1.
2.
Mounting
ED connection board CAN
7