DOTECH FX3DH Series Manual do utilizador - Página 7

Procurar online ou descarregar pdf Manual do utilizador para Controlador DOTECH FX3DH Series. DOTECH FX3DH Series 9 páginas. Digital temp. & humidity controller
Também para DOTECH FX3DH Series: Manual (4 páginas)

DOTECH FX3DH Series Manual do utilizador

Setting 2 Group

(PRG Button Push for 5 Sec.)
No
Menu
4 0076
Lock Function
4 0077
Sensor Type
4 0080
Correction of temperature sensor (※1)
4 0081
Decimal Point(PV) Display (※2)
4 0082
Correction of PV
4 0083
Sensor Input Filter (※3)
4 0084
Sensor Value Display Cycle
4 0085
Set Value(SV) Unification Mode
4 0086
Communication Address
4 0087
Communication Speed
Analogue Trans. Output
4 0088
(4~20mA) Mode
(-A1 model)
Analogue Trans. Output (20mA)
4 0089
(-A1 model)
Analogue Trans. Output (4mA)
4 0090
(-A1 model)
※1) Correction of temperature sensor : It is displayed when sensor input mode( IN ) set
※2) PV Decimal Point Display
※3) Sensor Input Filter Value

Current value (PV) trans. output

Output
20mA
4mA
RTL
RTH
Humidi cation(Heating)
proportional Control
Output
20mA
4mA
ST1-DF1
ST1
Code
OFF (0) : Lock cancel
LC 1 (1) : Setting 2 group lock
L O C
LC2 (2) : Setting 1,2 group lock
LC3 (3) : Setting 1, 2 group, Humidity & Temp. setup lock
H (0) : Use for humidity control only
T (1) : Use for temp. control only
I N
HT (2) : Use for humidity and temperature control
HTD (3) : Use for humidity control and temperature display
T C R
0. 1 (0) : Decimal point display
D P
C O R
S F T
S D T
OFF : Individual SV mode
S T O
(-R4 model)
A D R
48 : 4800BPS 96 : 9600BPS 1 92 : 19200BPS 384 : 38400BPS
(-R4 model)
B D R
PV (0) : PV Trans.
DIR (1) : Humidification(Heating) proportional Control
ReV (2) : Dehumidification(Cooling) proportional Control
A O M
ST 1 (3) : SV1(Set value) Trans.
ST2 (4) : SV2(Set value) Trans.
R T H
R T L
to Temp. & Humidity control mode or humidity control and temp. display mode.
: In case of setting as '1', it displays the current value with cutting the decimal place.
: It avoids hunting by giving temperature measuring delay.
set AOM to PV (Current value)
Input PV at 4mA output.
RTL
Input PV at 20mA output.
RTH
PV
set AOM to DIR (Humidi cation
(Heating) proportional Control)
Input SV at 4mA output.
ST1
Input DF at 20mA output.
DF1
PV
Unit
Step
°C
0.1
1 (1) : Do not display decimals
K
0.1
Sec
0.1
Sec
0.1
1
1
-
`
1
Dehumidi cation(Cooling)
proportional Control
Output
20mA
4mA
ST1

Set value(St) trans. output

Output
20mA
4mA
RTL
- 7 -
Min
Max
Default
OFF (0)
-1 9.9
99.9
-1 9.9
1 9.9
0.1
5.0
0
5.0
ON : Unifying SV mode
OFF (0)
1
1 28
-1 99
999
-1 99
999
set AOM to ReV (Dehumidi cation
(Cooling) proportional Control)
ST1
Input SV at 4mA output.
Input DF at 20mA output.
DF1
PV
ST1+DF1
set AOM to ST1-2 (set value)
Input SV at 4mA output.
RTL
RTH
Input SV at 20mA output.
St1~2
(SV)
RTH
Custom Setup
H (0)
0.0
0. 1 (0)
0.0
2.0
0.5
1
96
PV
1 00
0
R20160613