Voltage connection: Use cables with max cross-section of 2,5 mm
the applicable diagrams that follow.
Current connection: It is necessary to use external CTs with a primary rating adequate to the load to be measured and with a 5A or 1A secondary rating. Connect the CT output(s) to
the terminals marked I1, I2, I3 (CURRENT INPUT) of the instrument according to the applicable diagrams that follow.Use cables with cross-section adequate to the VA rating of the CT
and to the distance to be covered. The max cross-section for the terminals is 2,5 mm
N.B. The CT secondary must always be in short circuit when not connected to the instrument in order to avoid damages and risks for the operator.
Scrupulously respect the matching of phase between the voltage signals and current signals (RTD) and the direction of insertion of CT (P1-P2 and S1-S2). Failure to comply with this
correspondence and connection diagrams gives rise to measurement errors. (*) The grounding of S2 must be close to the CT and not near the instrument.
STAR 4W (4 WIRES) 3PH-4W LV
P1
P2
L1
S1
S2
P1
P2
L2
S1
S2
P1
P2
L3
S1
S2
N
V1
V2
V3
VOLTAGE INPUTS
*
1000 imp/kWh
1000 imp/kvarh
CURRENT INPUTS
I1
I2
S1 S2 S1 S2 S1 S2
TRIANGLE 3W (3 WIRES ) 3PH-3W
P1
P2
L1
S1
S2
P1
P2
L2
S1
S2
P1
P2
L3
S1
S2
V1
V2
V3
VOLTAGE INPUTS
*
1000 imp/kWh
1000 imp/kvarh
CURRENT INPUTS
I1
I2
S1 S2 S1 S2 S1 S2
TRIANGLE 2CT(3 WIRES ) 3PH-3W
P1
P2
L1
S1
S2
L2
P1
P2
L3
S1
S2
V1
V2
V3
VOLTAGE INPUTS
1000 imp/kWh
1000 imp/kvarh
CURRENT INPUTS
I1
I2
S1 S2 S1 S2 S1 S2
*
BI-PHASE (2 WIRES ) 2PH-2W
P1
P2
L1
S1
S2
L2
V1
V2
V3
VOLTAGE INPUTS
*
1000 imp/kWh
1000 imp/kvarh
CURRENT INPUTS
I1
I2
S1 S2 S1 S2 S1 S2
akse srl Via Aldo Moro, 39 42124 Reggio Emilia Italy
Tel. +39 0522 924 244 Fax +39 0522 924 245 [email protected] www.akse.it
P.I. 01544980350 R.E.A. 194296
VOLTAGE AND CURRENT CONNECTION
if stranded 4 mm
2
L1
L2
L3
N
17
18
19 20
21
POWER
AUX
SUPPLY
IN/OUT
Exa TR D6
Energy analyzer Transducer
*
AUX
RS-485
I3
IN/OUT
A B
10 11 12
L1
L2
L3
N
17
18
19 20
21
POWER
AUX
SUPPLY
IN/OUT
Exa TR D6
Energy analyzer Transducer
AUX
RS-485
I3
IN/OUT
A B
10 11 12
*
TRIANGLE 2CT (3 WIRES ) 3PH-3W
L1
L2
L3
N
17
18
19 20
21
POWER
AUX
SUPPLY
IN/OUT
Exa TR D6
Energy analyzer Transducer
AUX
RS-485
I3
IN/OUT
A B
10 11 12
N
17
18
19 20
21
POWER
AUX
SUPPLY
IN/OUT
Exa TR D6
Energy analyzer Transducer
AUX
RS-485
I3
IN/OUT
A B
10 11 12
Cap. Soc. Euro 85.800,00 i.v.
if rigid and connect them to the clamps marked VOLTAGE INPUT on the instrument according to
2
2
if stranded and 4 mm
2
STAR 4W (4 WIRES) 3PH-4W MV
P1
P2
S1
S2
P1
P2
S1
S2
P1
P2
S1
S2
V1
V2
V3
N
17
18
19 20
POWER
VOLTAGE INPUTS
SUPPLY
Exa TR D6
1000 imp/kWh
1000 imp/kvarh
Energy analyzer Transducer
CURRENT INPUTS
RS-485
I1
I2
I3
S1 S2 S1 S2 S1 S2
A B
TRIANGLE 2CT (3 WIRES ) 3PH-3W
P1
P2
S1
S2
P1
P2
S1
S2
V1
V2
V3
N
17
18
19 20
POWER
VOLTAGE INPUTS
SUPPLY
Exa TR D6
1000 imp/kWh
1000 imp/kvarh
Energy analyzer Transducer
CURRENT INPUTS
RS-485
I1
I2
I3
S1 S2 S1 S2 S1 S2
A B
P1
P2
S1
S2
P1
P2
S1
S2
V1
V2
V3
N
17
18
19 20
POWER
VOLTAGE INPUTS
SUPPLY
Exa TR D6
1000 imp/kWh
1000 imp/kvarh
Energy analyzer Transducer
CURRENT INPUTS
RS-485
I1
I2
I3
S1 S2 S1 S2 S1 S2
A B
*
POWER SUPPLY AND SERIAL LINE CONNECTION
The instrument is fi tted with a separate power supply. The power supply terminals are
numbered (17 e 18). Use cables with max cross-section of 2,5 mm
rigid.
if rigid.
STAR 4W (4 WIRES) 3PH-4W-BAL
P1
L1
S1
L2
L3
N
*
21
AUX
IN/OUT
AUX
IN/OUT
10 11 12
MONOFASE (2 WIRES) 1PH-2W
P1
P2
L1
S1
S2
N
*
21
AUX
IN/OUT
AUX
IN/OUT
10 11 12
TRIANGLE 2CT (3 WIRES ) 3PH-3W
P1
L1
S1
P1
P2
L2
S1
S2
L3
21
AUX
IN/OUT
AUX
IN/OUT
10 11 12
*
230-240VAC
FUSE
T 500mA
V1
V2
V3
N
17
18
19 20
POWER
VOLTAGE INPUTS
SUPPLY
Exa TR D6
1000 imp/kWh
1000 imp/kvarh
Energy analyzer Transducer
CURRENT INPUTS
RS-485
I1
I2
I3
S1 S2 S1 S2 S1 S2
A B
P2
S2
V1
V2
V3
N
17
18
19 20
21
POWER
AUX
VOLTAGE INPUTS
SUPPLY
IN/OUT
Exa TR D6
1000 imp/kWh
1000 imp/kvarh
Energy analyzer Transducer
CURRENT INPUTS
AUX
RS-485
I1
I2
I3
IN/OUT
S1 S2 S1 S2 S1 S2
A B
10 11 12
V1
V2
V3
N
17
18
19 20
21
POWER
AUX
VOLTAGE INPUTS
SUPPLY
IN/OUT
Exa TR D6
1000 imp/kWh
1000 imp/kvarh
Energy analyzer Transducer
CURRENT INPUTS
AUX
RS-485
I1
I2
I3
IN/OUT
S1 S2 S1 S2 S1 S2
A B
10 11 12
P2
S2
V1
V2
V3
N
17
18
19 20
21
POWER
AUX
VOLTAGE INPUTS
SUPPLY
IN/OUT
Exa TR D6
1000 imp/kWh
1000 imp/kvarh
Energy analyzer Transducer
CURRENT INPUTS
AUX
RS-485
I1
I2
I3
IN/OUT
S1 S2 S1 S2 S1 S2
A B
10 11 12
if stranded, 4 mm
2
21
AUX
IN/OUT
AUX
IN/OUT
10 11 12
Engineered and manufactured in Italy
Made
in
Italy
Pensato, progettato e prodotto in Italia
Subject to modifi cation without notice.
Edition 2015 04 24 ENG0031
if
2