Sensor in the IO-Link Communication Mode
3.1 Signal Path
The signal path describes the rough position of a parameter in the signal processing chain. The path starts
with the measuring value in the top left corner and finishes either with a physical pin (top right) or as output
via the process data (bottom right).
Measuring
Value
(Distance
)
Signal
Processing
Filtering
-
Disruption
-
filter
Signal
-
Adjustment
Etc.
-
Figure 3 Illustrates the signal path from raw data to an output either through a physical pin (top right) or as
output via the process data (bottom right)
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
SSC1:
Set Point
Configuration
SSC2:
Set Point
Configuration
Counter
Module
SSC 1
SSC 2
Switch
Counter
Source
Configuration
MDC Source
7/40
Output
Output Source &
Configuration
SSC 4
MDC
Process Data
Out
Baumer Electric AG