4.3.2.3 Hysteresis Alignment Mode (Only O200.G)
In case of axial detection tasks like stop trigger or level detection, an accurate switching distance is required.
To adapt the switching behavior and the hysteresis to the movement direction of the object, the alignment of
the hysteresis can be changed.
Only available for O200.G sensors.
Parameter name
Hysteresis.SSC1
Alignment
Left Aligned
4.3.2.3.1
Left Aligned defines the hysteresis to be aligned towards the sensor / against the sensing direction.
When to apply?
For an accurate switching distance in case the object is moving away from the sensor
-
Figure 12 Left Aligned, Single Point Mode
Right Aligned
4.3.2.3.2
Right Aligned defines the hysteresis to be aligned away from the sensor / in sensing direction.
When to apply?
For an accurate switching distance in case the object is moving towards the sensor.
-
Example: Stop trigger application, usual detection tasks.