Baumer Absolute encoder Manual - Página 17

Procurar online ou descarregar pdf Manual para Conversor de multimédia Baumer Absolute encoder. Baumer Absolute encoder 27 páginas. Absolute encoder with sae j1939

8.3

Response Frame format for PDU1

Description
DLC
Bit
8
Be aware, that the LSB is always transmitted before MSB. For example Index = 2104h, Byte 1 = 04h, Byte 2 = 21h.
8.4

Response Codes

Response-Code
Description
80h
Error occurred -> Check Error-Code
60h
Write command successfully
4Fh
Reading of 1 byte of data successfully
4Bh
Reading of 2 byte of data successfully
47h
Reading of 3 byte of data successfully
43h
Reading of 4 byte of data successfully
8.5

Error-Codes

Error-Code
Description
0504 0001h
Sent CMD is unknown
0601 0000h
Access to object unsupported
0601 0001h
Read-Access not supported to object
0601 0002h
Write-Access not supported to object
Object doesn't exist
0602 0000h
Sub-Index doesn't exist
0609 0011h
0609 0030h
Value out of Range
0609 0031h
Value too high
0609 0032h
Value too low