Baumer GXMMW Manual - Página 8

Procurar online ou descarregar pdf Manual para Conversor de multimédia Baumer GXMMW. Baumer GXMMW 26 páginas. Absolute encoder with powerlink interface
Também para Baumer GXMMW: Manual (41 páginas), Manual (19 páginas), Manual (24 páginas), Manual (19 páginas)

Baumer GXMMW Manual

5. Encoder operating parameters

Description of operating parameters
Parameter
Sense of rotation
Resolution
Measurement range Total resolution = number of steps per revolution x number of revolutions,
Preset value
Operating parameter values
Parameter
Sense of rotation
Resolution
Measurement range 1 to 67108864 (2
Preset value
Baumer_ProfibusDPV0_BIDE_MA_EN.docx
11.19
Significance
Behaviour of the output code depending on the sense of rotation of the shaft seen
looking at the flange
CW = Increasing values with clockwise rotation
CCW = Increasing values with counterclockwise rotation
Number of steps per revolution, input in integral steps
input in integral steps
A certain output value is assigned to the current position value (referencing)
Value range
CW/CCW
1 to 4096 – magtivo
1 to 8192 – multivo
1 to 262144 – activo/multivoPlus
) – magtivo
26
) – multivo
29
1 to 536870912 (2
31
1 to 2147483648 (2
)
– activo/multivoPlus
0 to (measurement range - 1 step)
Default setting
CW
4096
8192
262144
67108864
536870912
2147483648
0
8/26
Data type
Octet string
Unsigned 32
Unsigned 32
Unsigned 32
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany