9.4
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Speed (n):
• Range of switching speed
(ns ):
• Operating torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
• Interference immunity:
• Emitted interference:
• Approval:
MB104.3T1 - 11113957
ø165 mm
ø20 mm (through hollow shaft)
ø25 mm (through hollow shaft)
(as ordered)
≤500 N axial
≤650 N radial
IP67
≤6000 rpm
Pulses = 512:
Pulses = 1024: ±8...6000 rpm
Pulses = 2048: ±4...3500 rpm
Pulses = 2500: ±3...2900 rpm
Pulses = 4096: ±3...1750 rpm
≤15 Ncm
4.9 kgcm
Housing: aluminium
Shaft: stainless steel
-30...+85 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions CX (C5-M)
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
2x terminal box
4.2 kg
EN 61000-6-2
EN 61000-6-3
CE
Baumer_HOG165-DSL-T1_II_DE-EN (20A1)
±16...6000 rpm
2
9
38