Wash pump motor lubrication. You'll find two- (2) grease fitting on the top of the wash
6
pump motor, one- at each end. You'll need to grease these under normal conditions every
90 days. Use an electric motor bearing grease similar to Shell Dollum or Chevron SRI.
The removal of lime and or scale may be necessary at certain times. This will vary due
6
to the condition of your water. If you're finding lime and scale building up on the interior
walls of the machine, chances are they're also building up in the piping. This could
impair washing ability. You'll need to use some sort of lime and scale removal chemical.
Whatever you decide to use please make sure it's safe to use on stainless steel, bronze,
and brass. If you have any questions on what to use or how to use it, do not hesitate to
contact Douglas Machines Corp.
Electrical Connections – The first 6 months that you have your unit, you should go over all
6
wire connections in the electric panels as well as check the wire nuts on all motor leads.
After the first 6 months, you should only need to do this every 90 days.