10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
10)
MB072T2 - 11070661
Baumer_HOG11-HOG11G_T2_DE_EN_202203_MI_11070661 (22A1)
9...30 VDC
(HTL-P, TTL - version R)
10)
5 VDC ±5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz; ≤300 kHz option
K1, K2, K0 + inverted
Error output (option EMS)
HTL-P (power linedriver), TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE|UL-Zulassung / E217823, DNV approval (option)
ø105 mm
ø12...20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
≤450 N axial; ≤600 N radial
IP67
≤6000 rpm (mechanical)
6 Ncm
340 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-40...+100 °C
-25...+100 °C (>3072 pulses per revolution)
-50...+100 °C (option heating)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27, Shock 300 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions CX (C5-M)
according to ISO 12944-2
II 3 G Ex ec IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
Terminal box, 2x terminal box (option M)
1.6 kg; 1.8 kg (option M)
2.9 kg (option G); 3.3 kg (option G + option M)