Baumer Hubner Berlin microGen PMG10 Profibus DP Manual de instruções - Página 25
Procurar online ou descarregar pdf Manual de instruções para Conversor de multimédia Baumer Hubner Berlin microGen PMG10 Profibus DP. Baumer Hubner Berlin microGen PMG10 Profibus DP 40 páginas. Absolute encoder
Baumer Hübner
6.1.4.1
Setting the terminating resistor
ON = final bus user
OFF = any bus user
6.1.4.2
Setting the bus user address
1. Digit user address
2. Digit user address
(Illustration shows example user address 23).
6.2
Terminal box
6.2.1
Pin assignment at terminal box
Connection
I
Ub
I
0V
I
A+
I
A-
I
B+
I
B-
I
R+
I
R-
I
nE+
I
nE-
II
SP+
II
SP-
IV
SA
IV
SB
dnu
I
Additional output incremental (optional)
II
Speed switch (optional)
III
According to product variant
IV
Programming interface (programmable product variant only)
V1 | PMG10 & PMG10P Profibus DP
Description
Operating voltage
Ground connection
Output signal channel 1
Output signal channel 1 inverted
Output signal channel 2 (90° shift to channel 1)
Output signal channel 2 inverted
Zero pulse (reference signal)
Zero pulse inverted
System OK+ / Error output
System OK / Error output inverted
DSL_OUT1 / speed switch (open collector
DSL_OUT2 / Speed switch (0 V
RS485+ / programming interface
RS485 / programming interface
do not use
III
or semiconductor relay
III
or semiconductor relay
Operating Manual
Electrical installation
|
6
III
)
III
25