Baumer Hubner PMG10 Instruções de montagem e de utilização - Página 16
Procurar online ou descarregar pdf Instruções de montagem e de utilização para Conversor de multimédia Baumer Hubner PMG10. Baumer Hubner PMG10 36 páginas. Absolute encoder ssi with magnetic sensing
ELECTRICAL CONNECTION / TERMINAL SIGNIFICANCE
5.
ELECTRICAL CONNECTION
5.1
Terminal significance
Ub
0V
A+
1)
A−
1)
B+
1)
B−
1)
R+
1)
R−
1)
nE+
nE−
PRE
DIR
SP+
2)
SP−
2)
SA
3)
SB
3)
D+
D−
C+
C−
dnu
* Depending on version
Additional output incremental (option)
1)
Speed switch (option)
2)
Programming interface (only PMG10P)
3)
13/29
Voltage supply
Ground
Output signal channel 1
Output signal channel 1 inverted
Output signal channel 2 (offset by 90° to channel 1)
Output signal channel 2 inverted
Zero pulse (reference signal)
Zero pulse inverted
System OK+ / error output
System OK− / error output inverted
RESET (see also
section
Rotating direction (see also
DSL_OUT1 / speed switch (open collector* or solid state relay*)
DSL_OUT2 / speed switch (0V* or solid state relay*)
RS485+ / programming interface
RS485− / programming interface
SSI data+
SSI data−
SSI clock+
SSI clock−
Do not use
5.2.2)
section
5.2.3)
MB245EN - 11171693, 19A3, Baumer_PMG10-SSI_II_EN