8.

Dimensional drawings

KTD 3-... A 4 L Y 9
mounting side
(proposition)
Type
KTD 3-1 A 4 L Y 9
KTD 3-2 A 4 L Y 9
KTD 3-3 A 4 L Y 9
KTD 3-4 A 4 L Y 9
KTD 3-6 A 4 L Y 9
KTD 3-... A 4 L Y11
mounting side
(proposition)
spacer
25
Type
KTD 3-1 A 4 L Y11
KTD 3-2 A 4 L Y11
KTD 3-3 A 4 L Y11
KTD 3-4 A 4 L Y11
KTD 3-6 A 4 L Y11
16
mounting kit 052
(standard)
7
2 set screws
DIN EN ISO 4029
- M4x5
30
7
VDC
a
10
65.5
d =ø10 mm - ø16 mm
20
65.5
Please specify the desired
bore diameter in your order.
30
65.5
40
75.5
Please specify the desired
60
75.5
mounting kit in your order.
mounting
kit 056
7
(standard)
30
7
VDC
a
10
65.5
d =ø10 mm - ø16 mm
65.5
20
Please specify the desired
bore diameter in your order.
30
65.5
40
75.5
Please specify the desired
60
75.5
mounting kit in your order.
Baumer_KTD3A4-KTD3B10-KTD3-Kombinationen_OI_DE-EN_1606.indd
Pg 7
ground
terminal M4
a
Pg 7
ground
terminal M4
cylinder head screw
DIN EN ISO 4762
- M5x40
A/F4
tightening torque
a
max. 4.7 Nm
30
flexible
30
torque support
6.6
flexible
torque
support
018-24 Y 9