A.2 Specifications

Input Characteristics

Input Voltage Range
Range 1
Range 2
Input Frequency Range
Maximum Input ac Current
Inrush Current
Efficiency

Output Characteristics

Output
Voltage
+5V
+12V
1
+12V
2
-12V
+5VSB
+3V3

Over-Voltage Protection (OVP)

Output Voltage
+5V
+12V
+3.3V
+5VSB
-12V
NOTE
The power supply will shut down and latch off for shorting +5V,
+12V, -12V, or +3.3V. By shorting +5VSB, the power supply can
latch down or automatically recover when the fault condition is
removed. This requires disconnecting then re-connecting the AC
power plug.
ASUS AP1600R 1U Rackmount Server
Min
90V
180V
47 Hz to 63 Hz
4.96A max. at 100Vac
2.48A max. at 200Vac
2.75A max. at 230Vac, maximum load
30A cold start
30A warm start
72% min. at nominal input,
maximum load
Load Range
Min
Max
1.0A
12.0A
1.5A
16.0A
0.5A
16.0A
0A
0.5A
0.1A
2.0A
1.5A
16.0A
Maximum Voltage
6.2V
14.5V
4.5V
6.5V
-14.5V
Nom
100V
240V
Regulation
Min
Max
-4%
+5%
-4%
+5%
-4%
+5%
-5%
+9%
-4%
+5%
-3%
+5%
Max
140V
264V
Ripple
Max
50mV
p-p
120mV
p-p
120mV
p-p
120mV
p-p
50mV
p-p
50mV
p-p
43