Figure 35 ▲
Operation of two camer-
as employing  a Gigabit 
Ethernet switch.
Data  processing  within 
the  switch  is  displayed 
in the next two figures.
Figure 36 ►
Operation  of  two  cam-
eras employing a
minimal  inter  packet 
gap
(IPG).
Max. IPG:
On the Gigabit Ethernet
the max. IPG and the data
packet must not exceed 1
Gbit. Otherwise data pack-
ets can be lost.
Figure 37 ►
Operation of two camer-
as employing an optimal 
inter packet gap (IPG).
28
5.3.1 Example 1: Multi Camera Operation – Minimal IPG
Setting the IPG to minimum means every image is transfered at maximum speed. Even 
by using a frame rate of 1 fps  this results in full load on the network. Such "bursts" can 
lead to an overload of several network components and a loss of packets. This can occur, 
especially when using several cameras.
In the case of two cameras sending images at the same time, this would theoretically oc-
cur at a transfer rate of 2 Gbits/sec. The switch has to buffer this data and transfer it at a 
speed of 1 Gbit/sec afterwards. Depending on the internal buffer of the switch, this oper-
ates without any problems up to n cameras (n ≥ 1). More cameras would lead to a loss of 
packets. These lost packets can however be saved by employing an appropriate resend 
mechanism, but this leads to additional load on the network components�
5.3.2 Example 2: Multi Camera Operation – Optimal IPG
A better method is to increase the IPG to a size of
optimal IPG = packet size + 2 × minimal IPG
In this way both data packets can be transferred successively (zipper principle), and the 
switch does not need to buffer the packets�