Baumer SXC20 Manual do utilizador - Página 13

Procurar online ou descarregar pdf Manual do utilizador para Câmara digital Baumer SXC20. Baumer SXC20 48 páginas. Sxc series cameralink cameras with truesense imaging sensors
Também para Baumer SXC20: Manual de início rápido (2 páginas)

Baumer SXC20 Manual do utilizador
6.2.

Timings

The image acquisition consists of two seperate, successively processed components.
Exposing the pixels on the photosensitive surface of the sensor is only the first part of the 
image acquisition. After completion of the first step, the pixels are read out.
Thereby the exposure time (t
ed for the readout (t
readout
Baumer  cameras  can  be  operated  with  two  modes,  the  Free Running Mode and the
Trigger Mode.
The cameras can be operated non-overlapped
used, and the combination of exposure and readout time:
Non-overlapped Operation
Here the time intervals are long enough
to process exposure and readout succes-
sively.
Exposure
Readout

6.2.1. Free Running Mode

In the "Free Running" mode the camera records images permanently and sends them to 
the PC. In order to achieve an optimal (with regard to the adjusted exposure time t
and image format) the camera is operated overlapped.
In case of exposure times equal to / less than the readout time (t
mum frame rate is provided for the image format used. For longer exposure times the
frame rate of the camera is reduced.
Exposure
Readout
Flash
t
= t
flash
exposure
Notice
For the employment of partial scan, the camera needs to be stopped.
*)
Non-overlapped means the same as sequential.
) can be adjusted by the user, however, the time need-
exposure
) is given by the particular sensor and image format.
*)
In this operation the exposure of a frame
(n+1) takes place during the readout of 
frame (n).
Exposure
Readout
t
t
exposure(n)
exposure(n+1)
t
readout(n)
t
t
flash(n)
flash(n+1)
t
flashdelay
or overlapped. Depending on the mode
Overlapped Operation
 ≤ t
exposure
t
readout(n+1)
exposure
), the maxi-
readout
Timings:
A - exposure time
frame (n) effective
B - image parameters
frame (n) effective
C - exposure time
frame (n+1) effective
D - image parameters
frame (n+1) effective
Image parameters:
Offset
Gain
Mode
Partial Scan
13