Baumer SXC80 Manual do utilizador - Página 33

Procurar online ou descarregar pdf Manual do utilizador para Câmara digital Baumer SXC80. Baumer SXC80 48 páginas. Sxc series cameralink cameras with truesense imaging sensors
Também para Baumer SXC80: Manual de início rápido (2 páginas)

Baumer SXC80 Manual do utilizador
8.4.3.

Defectpixellist

As stated previously, this list is determined within the production process of Baumer cam-
eras and stored in the factory settings (see 4.8.).
8.5.
Process
Interface
8.5.1.

Digital IOs

Cameras of the Baumer SX series are equipped with three input lines and three output 
lines.
8.5.1.1.
IO
Circuits
Notice
Low Active: At this wiring, only one consumer can be connected. When all Output pins 
(1, 2, 3) connected to IO_GND, then current flows through the resistor as soon as one 
Output is switched. If only one output connected to IO_GND, then this one is only us-
able.
The other two Outputs are not usable and may not be connected (e.g. IO Power V
Output high active
Camera
Customer Device
IO Power V CC
U
Pin
ext
I OUT
Out (n)
Pin
R L
IO GND
8.5.1.2.
User Definable
The wiring of these input connectors is left to the user.
Sole exception is the compliance with predetermined high and low levels (0 .. 4,5V low,
11 .. 30V high).
The defined signals will have no direct effect, but can be analyzed and processed on the 
software side and used for controlling the camera.
The employment of a so called "IO matrix" offers the possibility of selecting the signal and 
the state to be processed.
On the software side the input signals are named "Line0", "Line1" and "Line2". 
Output low active
Camera
Customer Device
U
Pin (Out1, 2, 3)
ext
I OUT
Out1 or Out2
or Out3
Inputs
state selection
(software side)
state high
(Input) Line0
state low
state high
(Input) Line1
state low
state high
(Input) Line2
state low
IO Matrix
Input
Customer Device
IO Power V CC
DRV
R L
Out
IO GND
IO GND
Line0
Line1
Line2
)!
CC
Camera
IN1 Pin
IN GND Pin
◄ Figure 35
IO matrix of the 
Baumer  SXC  on  input 
side.
33