10 Display and user menu

Scatec-10 /-15 allows the user to set the parameters in two ways:
manually by means of the keypad and the display
-
by means of a PC, an adapter set, and the application software ScaDiag (refer to the ScaDiag-manual)
-
10.1 General
In its normal state, the 2-line LCD- display shows the total number of detected edges on the upper line since
the last counter reset and the name of the sensor (either Scatec-15 or Scatec-10) on the lower line.
The parameter setting is performed within a user menu. To navigate to a submenu in order to change a
parameter value is shown in section 10.2 Navigation.
User manual Scatec-10 / -15
Version 2017-10
Threshold
20 to 799 in steps of 1
to define the value which marks the
beginning of an edge when the ratio v/r
drops below this value.
This parameter is accessible only if menu
C16 customized sensitivity mode was
previously activated (C15 = 1).
Hysteresis
1 to 499 in steps of 1
to define how much the ratio v/r must rise
above threshold in order to initiate the end
of an edge.
This parameter is accessible only if
previously
in
menu
sensitivity mode was activated (C15 = 1).
www.baumer.com
[Threshold]
[Sens. Hyster.]
C15
customized
24 / 44
Scatec-1x
V
R
Laser
Hysteresis
Beginning of edge
(described in this manual)
Baumer Electric AG
Frauenfeld, Switzerland
Threshold
time
End of edge