M-Series Tester
User's Manual
2. Installation (continued)

2.2 Connecting PWM Sensors

To connect a PWM sensor equipped with MTS' M12 integrated connector system to the M-Series Tester use the following procedure:
1. Use the provided cabling fitted with the M12 connector and connect the M12 cable to the MTS M12 integrated connector system on the sensor or cylinder.
(continue with step 3 below) OR
To connect a PWM sensor not equipped with MTS' M12 integrated connector system:
1. Use the Pigtailed cable that is included in the test kit to connect the ends without banana plugs to the customer's specified interface/connector that mates to the
M-Series sensor or cylinder.
2. Ensure that the wire colors of the cable correspond with the wire colors of the output wires from the sensor.
3. Plug the brown banana plug into the +12 Vdc or +5 Vdc (depending on voltage required by the sensor) terminal on the top of the tester.
4. Plug the white banana plug into the DC GND terminal on the top of the tester.
5. Plug the green banana plug into the PWM terminal at the top of the tester.
− − − −
Select sensor
supply voltage
(+12 V or +5 V)
− − − −
Select sensor
supply voltage
(+12V or +5V)
MTS Sensors
+5V
GND
ANA
PWM
+12V
M12 Cable Assembly
+5V
GND
ANA
PWM
+12V
CUSTOMER
SPECIFIED
INTERFACE/
CONNECTOR
Green
White
Brown
Pigtail cable
assembly
Sensor cable
Green
White
Brown