Dover PSG Blackmer LGL154A Instruções de instalação, operação e manutenção - Página 2
Procurar online ou descarregar pdf Instruções de instalação, operação e manutenção para Bomba de água Dover PSG Blackmer LGL154A. Dover PSG Blackmer LGL154A 12 páginas. Liquefied gas pumps
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Hazardous
machinery can
cause serious
personal injury.
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury or property damage.
Hazardous pressure
can cause serious
personal injury or
property damage
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Hazardous or toxic
fluids can cause
serious injury.
PUMP IDENTIFICATION
A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is
recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if
information pertaining to the pump is required, this data must be furnished to a Blackmer representative.
TECHNICAL DATA
Maximum Pump Speed
Maximum Operating Temperature
Maximum Differential Pressure
Maximum Working Pressure
Technical Data is for standard materials of
construction. Consult Blackmer Material Specs for
optional materials of construction.
These pumps are listed by Underwriters' Laboratories
for liquefied petroleum gas (LPG) service
SAFETY DATA
PUMP DATA
1750 RPM
240°F
(115°C)
LGL158: 200 PSI (13.8 Bar)
LGL156: 160 PSI (11.0 Bar)
LGL154: 140 PSI (9.6 Bar)
425 PSI
(29.3 Bar)
501-K00
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous voltage.
Can shock, burn or
cause death.
Failure to relieve system pressure prior
to performing pump service can cause
serious personal injury or property
damage. Systems with meters will still
be pressurized even after the hose is
Hazardous pressure
emptied
can cause serious
personal injury or
property damage
Operation without guards in place can
cause serious personal injury, major
property damage, or death.
Do not operate
without guard
in place
INITIAL PUMP START UP INFORMATION
Model No.: ____________________________________
Serial No.: ____________________________________
ID No.: _______________________________________
Date of Installation: _____________________________
Inlet Gauge Reading: ____________________________
Discharge Gauge Reading: _______________________
Flow Rate: _____________________________________
Page 2/12