MAINTENANCE AND SERVICE

For safe and consistent operation of TWG hoists, gearboxes, and winches, a regular program of
preventive maintenance is strongly recommended. Regular oil changes with the correct oil and
frequency for the application and an annual inspection of the wear components will help ensure
a long life for your planetary geared products.
Maintenance Scheduling
Manufacturer recommends changing oil after first 50 hours of operation. All gearboxes require
the proper EP gear oil for lubrication. Some units may be equipped with a grease fitting for
lubrication of the output shaft bearings (pinion up applications). The shaft bearings should be
greased sparingly at every 50 operating hours with an EP lithium or GP bearing lube. For pinion
down applications, gearbox oil will lubricate shaft bearings
Oil Level Maintenance
Tulsa Winch recommends that the oil be checked and adjusted as part of the pre-use
inspection. If the oil level drops frequently or oil leakage is detected during an inspection,
maintenance should be performed to correct any problems.
Oil Change Interval
The oil in the gearbox and brake sections (if applicable) should be changed every 1000 hrs or
6 months of usage.