2.OO installation (continued)
2.O5 Electrical Connections
Main Input Power: Connect a 110 to 230 VAC source to
the X1 connections in the cabinet.
Remember never to get the power from a washer extractor.
An independent 10 amp breaker is recommended.
The power cable must be constructed of 3 wires with at
least 1.5 mm cross-section or 16 gauge wire.
•
Line/Phase (black) goes to the 'L' connector.
•
Neutral (white) goes to the 'N' connector.
•
Ground (green) goes to the 'Ground' connector.
Once the power is supplied to the unit, all inputs, outputs
and communications may be configured.
Distributor Connections: Follow the wiring diagrams to below, when making the electrical connections between the main
panel and the distributor control cabinet
Bottom of Control Cabinet
Recommended
distributor cable
cabinet routing
Washer Signal Wiring: (Metric Models)
Be sure the unit is turned off, before connecting
the washer signals to the control cabinet.
1) Attach the signal wires from the washer to the appropriate
Washer Signal Voltage Adapter Board, based on the
signal voltage coming from the washer.
2) Plug the Adapter Board into the appropriate Washer Signal Connection header at the bottom of the main board in the
control cabinet.
Note: Every unit ships with a total of 9 washer adapter boards, a full set of 3 for each of the 3 voltage options.
Bottom of Control Cabinet
Recommended
washer signal cable
cabinet routing
6
Inside
Control Cabinet
+
+
-
-
Weidmuller
DC OK
Ajust
22-28V
PROeco
3-5A Char.C
L(+)
N(-)
PE
X1
Inside
Control Cabinet
+
+
-
-
Weidmuller
DC OK
Ajust
22-28V
PROeco
3-5A Char.C
L(+)
N(-)
PE
1 2
3
Washer Signal
Connections
Bottom of Control Cabinet
Recommended
power cord
cabinet routing
Main Input Power
(110 to 230 VAC)
X2
X3
Inside
Control Cabinet
X2
X3
X1
Distributor
Control
Cabinet
Distributor
Connections
1 2 3 C
Washer
Washer Voltage
Signal Voltage
Adapter Board
220 VAC
Option 1
110 VAC
Option 2
24 VAC or DC
Option 3
Washer Machine Signal Wires
C
5
4
3
2
1
Machine 1
+
+
-
-
Weidmuller
DC OK
Ajust
22-28V
PROeco
3-5A Char.C
L(+)
N(-)
PE