CONTROLS
The lower air controls (located at the bottom of the doors)
and the upper air controls (located at the top of the doors)
should be fully open until the fire is established. Closing
the air controls while the fire is cold will cause fast
sooting up of the door glass and chimney.
When the fire is well established, operate as follows:
MODEL 1800W
Operate the heat output by adjustment to the air controls
located at the bottom of the doors.
MODEL 2700W
For woodburning, leave both the top and the bottom air
controls fully open. When a hot fire is established, close
the bottom air controls. The burning rate can then be
controlled by adjustment to the top air controls. When
burning solid fuels on the 2700W, the above is reversed
and the burning rate is controlled by adjustment to the
lower air controls.
MODEL 2000MFR
For woodburning, leave both the top and the bottom air
controls fully open. When a hot fire is established, close
the bottom air controls. The burning rate can then be
controlled by adjustment to the top air controls. When the
appliance is used with the doors in the open position (as
an open fireplace) the burning rate can be controlled by
adjusting the front air slide control in front of the ash
compartment.
For overnight burning, fully close the lower air control
and partly close or fully close the top air controls (if
fitted).
IMPORTANT
NEVER ALLOW THE GRATE TO BECOME
"SANDWICHED" IN ASH. THE UNDERSIDE OF THE
GRATE MUST NEVER BE IN CONTACT WITH ASH.
FAILURE TO OBSERVE THIS ADVICE WILL LEAD TO
PREMATURE WEAR OF THE GRATE.

TROUBLESHOOTING

PROBLEM
CAUSE OF PROBLEM
SMOKE ENTERING ROOM FROM
If burning wood, make sure it is well seasoned with moisture content well below 20%. This
APPLIANCE
usually requires the wood to be seasoned for 2-3 years. Trying to burn "green wood" is like
trying to burn water!
Ensure you are not closing the air controls before the fire is established (see section on
operation).
Check for blockage in chimney (consult your chimney sweep if necessary).
If problems persist, arrange for your dealer or professional chimney specialist to report on the
suitability of your chimney.
TAR FORMATION
Use of unseasoned wood.
Poor chimney draught.
Operating appliance while the fire is at very low temperature.
FUMES ENTERING ROOM
Seals on flue joints in convection chamber are not "smoke tight".
THROUGH AIR GRILLS
Walls of convection chamber are not clean.
CAST IRON GRATES DISTORTING
Ash compartment over full causing the grates to be sandwiched in hot ash.
CARE OF YOUR DOVRE APPLIANCE
The Dovre 2000 is constructed from high quality cast iron
and finished with a special high temperature resistant
paint. To ensure a good appearance is maintained, the
cast iron surfaces should be brushed using a soft clean
brush. Never attempt to clean the stove whilst it is under
fire. One a year, the doors can be treated with a new coat
of paint using Dovre high temperature resistant paint
available from your stockist.
GLASS
Clean the glass daily whilst the glass is warm (not hot).
Use a damp soft cloth with a little mild detergent. Never
use harsh abrasives. If the glass is coated with heavy tar
deposits, use Dovre Ceraclean glass cleaner. Never allow
excessive tar deposits to build up.
DOVRE 2000 GAS MODELS
If fitting a DOVRE gas burner to your Dovre 2700W,
please refer to the separate installation instructions
issued with the burner.
It is important that you also ensure that following steps
are taken if a gas burner is fitted.
Remove any flue damper that may be fitted to the
appliance.
Ensure that the appliance doors are locked in the "open
position"

ANNUAL MAINTENANCE

1
Remove the rope seals from the doors.
2
Clean out rope channels using a wire brush.
3
Fit new Dovre rope seal using the special adhesive
supplied in the Dovre Service Kits (these can be
obtained from your Dovre stockist).
4
Lightly grease all hinges on doors with graphite
grease.
6
DOVRE 10 YEAR WARRANTY
If the castings on this appliance should prove to be defective within ten years of the
purchase date, the faulty castings will be replaced free of charge, subject to the
following conditions.
1. The purchaser shall complete the registration section below and return it within
seven days of purchase. Failure to return the registration could result in delays in
processing any claims.
2. The appliance shall have been installed in compliance with the installation
instructions.
3. The appliance shall not have been used for the burning of unseasoned wood.
4. This warranty only applies to the appliance body castings and does not include
renewable components including grates, ashpans, glass, seals and baffle plates.
5. This warranty does not cover site visits and labour charges.
This warranty does not affect the Statutory Rights of Consumer Purchasers.
Please complete and return this section within seven days of purchase to:
Dovre Castings Ltd, Weston Works, Weston Lane, Tyseley, Birmingham B11 3RP.
NAME:
ADDRESS:
TELEPHONE NUMBER:
MODEL:
DATE OF PURCHASE:
DEALER:
7