Connect utilities to docking assembly.
6.1
Water and drain
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
• Rough-in ice machine potable water
supply
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
pipe/drain
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4 mm/0,3 m).
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
10
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
.
.
.

External connections

6.2
Refrigerant
• Braze supplied quick-connect lines onto
stub-ins
remote condensing
.
DROP-IN • RIDE Technology