Chapter 2
This chapter discusses components inside the ReadyPanel enclosure. These components include the
memory, display power inverter, touch screen controller card, cables, and the ReadyBoard Single Board
Computer (SBC).
NOTE
Refer to the specific ReadyBoard Reference Manual for more information than
this chapter provides.

ReadyPanel Assembly Procedures

The following procedures describe how to gain access to the ReadyPanel internal components and
the ReadyBoard memory.

Tools Required

Use these tools to install and remove components into or out of the ReadyPanel enclosure.
Phillips #2 screwdriver
Anti-static service kit - Use a complete anti-static service kit (or the equivalent) to remove or
install the ReadyBoard. A complete anti-static service kit should include a static-dissipating
work surface, a chassis clip lead, and a wrist or ankle strap.

Opening the ReadyPanel Enclosure

Always use the following procedure when gaining access to the ReadyPanel's internal
components.

To remove the cover of the ReadyPanel

1.
Initiate a shut down sequence through the OS, or hold in the reset switch for 4-6 seconds to turn off
power. See
Figure 1-3 on page
2.
Make sure the power LED on the front panel is completely inactive. See
3.
Disconnect the power cable from the DC Power In connector of the I/O panel.
CAUTION
4.
Remove the cover from the ReadyPanel enclosure. See
a.
Turn over the ReadyPanel so that the touch screen faces down on an anti-static surface.
b.
Remove the four cover screws that mount the cover to the enclosure.
c.
Lift the cover up from the enclosure.
d.
Unplug the fan cable from the fan connector on the ReadyBoard.
e.
Set aside the cover and screws for later re-installation.
ReadyPanel
ReadyPanel Components
5.
Components on the ReadyBoard are sensitive to static electricity and can
be easily damaged by improper handling. Do the following when
handling the ReadyBoard.
Always use an anti-static wrist/ankle strap and a grounding mat.
Before you handle the ReadyBoard, touch a grounded, unpainted metal
surface to discharge any static electricity.
User's Guide
Figure 1-3 on page
Figure
2-1.
5.
9