Follett 18690 Manual de instalação, operação e serviço - Página 11
Procurar online ou descarregar pdf Manual de instalação, operação e serviço para Frigorífico Follett 18690. Follett 18690 19 páginas. High-performance compact refrigerators
Installing Third-party Temperature Probe
Facilities using a third-party alarming and/or temperature monitoring
system need to install the third-party probe in the refrigerator. Follett
recommends removing any stored product before performing this
procedure.
Refer to for instruction to disable Follett integral alarming to eliminate
confusion between two monitoring services.
1. Move the power switch on lower rear panel to OFF and unplug
the refrigerator.
2. Remove the rear panel of the refrigerator (Fig. 11).
3. Open front door of refrigerator and remove shelf/shelves, if
installed, for better access.
4. From inside the refrigerator, push and fold the perforated cut out
located on the inside, upper-right hand corner (Fig. 12).
5. Use a long screwdriver or drill to create a hole (up to 1"
(25.4 mm) diameter) through the exposed foam insulation.
6. From inside the refrigerator, feed non-probe end of wire through
opening (Fig. 13).
7.
Secure probe to interior cabinet wall to avoid product
interference.
8. Gently pull on non-probe end of wire to remove slack from
inside of refrigerator.
9. Use Permagum* or equivalent sealant to replace foam
insulation (removed in Step 5) to ensure proper performance of
refrigerator.
10. Remove any debris that may have fallen into the drain pan or
condensor area.
11. Route non-probe end of wire through appropriate ventilation
hole in refrigerator rear panel.
12. Reinstall the rear panel.
13. Connect non-probe end of wiring to monitoring device.
14. Plug in the refrigerator and return the power switch to ON.
15. Follow instructions found in
disable alarm functions.
* Permagum is a registered trademark of the Presstite Engineering Company.
Disabling the Alarm on page 8
Fig. 11
Fig. 12
Fig. 13
to
REF1/REF2 Compact Refrigerators
11