Amprobe ACD-40PQ Manual do utilizador - Página 11
Procurar online ou descarregar pdf Manual do utilizador para Instrumentos de medição Amprobe ACD-40PQ. Amprobe ACD-40PQ 17 páginas.
Display Backlight (model ACD-16 TRMS & ACD-40PQ only)
P
ress the SELECT button for 1 second or more to toggle the display backlight on and off.
Auto Power Off (APO)
The meter turns off after approximately 16 minutes of neither switch nor button activity. To
wake up the meter from APO, slide the function-selector to other positions and back on
a
gain. Always turn the function-selector to OFF when the meter is not in use.
Disabling Auto-Power-Off (APO)
Press-and-hold the HOLD button while sliding the function-selector to a (designated)
function-selector position. This disables the Auto-Power-Off feature of the functions on that
particular function-selector position. The LCD displays "
right after the HOLD button is released. Slide the function-selector to any other positions
a
fterwards resumes Auto-Power-Off feature.
RS232C PC computer interface capabilities
The instrument is equipped with an optical isolated data output port at the bottom case
near the battery compartment. Optional purchase PC interface kit RS232 KIT2
(including Optical Adapter Back, RS232 Cable & Bs13x Software CD) is required to
connect the meter to PC computer thru RS232C protocol. The RS232C Data
Recording System software Bs13x includes a digital meter, an analog meter, a
comparator meter, and a Data Graphical recorder. Refer to the README file comes
w
ith the interface kit for further details.
5) MAINTENANCE
WARNING
To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from
the input jacks and turn OFF the meter before opening the case. Do not operate with open
c
ase.
Trouble Shooting
If the instrument fails to operate, check batteries and test leads etc., and replace as
necessary. Double check operating procedure as described in this user's manual
If the instrument voltage-resistance input terminal has subjected to high voltage transient
(caused by lightning or switching surge to the system) by accident or abnormal conditions of
operation, the series fusible resistors will be blown off (become high impedance) like fuses to
protect the user and the instrument. Most measuring functions through this terminal will then
be open circuit. The series fusible resistors and the spark gaps should then be replaced by
qualified technician. Refer to the LIMITED WARRANTY section for obtaining warranty or
repairing service.
1.800.561.8187
www.
.com
" & "
" to confirm activation
10