1.2 Inlet Water Cooling Requirements: 1.5 GPM @ 690 kPa (100 psi) max, 35° C
Max.
1.3 Coolant type: Water
2.
Storage and Transportation
2.1 Storage temperature/humidity/air pressure: -25 to +70° C (class 1k4 per
prEN50178), 5 - 95% humidity (non-condensing, no formation of ice, class 1k3),
70-106 kPa (class 1k4).
2.2 Transport temperature/humidity/air pressure: -25 to +70° C, 5 - 95% humidity,
70-106 kPa (class 2k3).
3.
This equipment has been designed to be compliant with FCC Part 18 emission standards
for EMI/RFI radiation. Radiated emissions shall also not exceed maximum levels
permitted by ANSI C95.1-1982 standards on safety levels with respect to human exposure
to RF and electromagnetic fields from 300KHz to 100GHz.
F. Testing Specifications
1. Production Acceptance Test: Each unit will be required to "pass" production acceptance
testing and a "Final Test Report" will be generated to document results.
1.1 Production Acceptance Testing process shall include as a minimum: Complete
Parametric/Functional Tests covering: line regulation, calibration, linearity, burn-
in, over-temp test, open circuit test, MAX power test, harmonic distortion, AC
ripple, and remote interface tests. Data sheet for each generator to be shipped
with unit.
G. Packaging & Shipping Specifications
1. Accessories Supplied
1.1 Final test results
1.2 Operating manual
2. Shipping
NOTE: If there is a conflict between this document and customer Purchase Order
then the latter supersedes.
NOTE FOR REPAIRS: Unless repairs have accessories included with them and
have them listed on the Return Material Authorization (RMA) Tag, returned materials
will not have to fulfill procedural requirements for accessories.
8