SPECIFICATIONS
Operating voltage
LOW Range: 30 to 1500 VAC; HIGH Range: 1500 VAC to
122 kVAC
Operating Temperature: 0°C to +52°C (32°F to +125°F);
RH < 90%
Storage Temperature: 0°C to +52°C (32°F to +125°F)
battery removed
Environment: < 2000 m (1.24 mi), outdoor operation
Power: 9 V alkaline battery
Power Consumption:
• OFF: 60 uA
• Low Detection mode: 39 mA
• High Detection mode: 39 mA
Duty Cycle: Continuous
Response Time: Instantaneous
Dimensions: 345(L) x 75(W) x 47(H) mm (13.5 x 3.0 x 1.8 in)
Weight: 243 g (0.5 lb)
Optional Accessory: TIC 410A Hot Stick
Electromagnetic Compatibility (EMC): EN 61326-1
Korea (KCC): Class A Equipment (Industrial Broadcasting
& Communication Equipment)
This product meets requirements for industrial (Class
[1]
A) electromagnetic wave equipment and the seller or
user should take notice of it. This equipment is intended
for use in business environments and is not to be used
in homes.