DPK System JA-60P Manual - Página 2

Procurar online ou descarregar pdf Manual para Sensores de segurança DPK System JA-60P. DPK System JA-60P 4 páginas. Wireless p.i.r. motion detector

JA-60P –
,
.
. JA-60P
,
.
.
PIR
3 - 2
1,5
1
2
2,5
12 /120 (
0,1 /
4 /
60
.
100
(
)
433,92
EN 50131-1
2
, -10
, JA-60P
.
2
2,5
.
12
,
-
,
. JA-60P
,
.
(
,
A.
,
,
.
,
,
.
B.
(
).
.
.
C.
(
1/3
).
(
)
,
DIP
#1
OFF –
,
.
ON –
,
.
.
#2
JA-60P
JA-60P
OFF –
ON –
.
,
.
.
(
.
.
60
,
.
,
,
;
,
(
.
).
)
,
,
.
2,5
[m]
2
+40
1,5
1
0,5
1,6
3,7
120
º
5
120 .
).
.
. .).
.
.
,
5
.
,
,
.
,
.
,
.
.
,
.
.
,
.
,
.
.
,
(
,
).
.
#2.
60
,
,
.
,
(
).
- 4 -
.
The JA-60P is an intruder detector designed to detect human body
movement in a protected area. Digital processing insures a high immunity
to false alarms and outstanding stability. The JA-60P uses a sophisticated
,
radio communication protocol with a high level of data safety. The detector
makes regular auto testing and reports its conditions regularly to the system
for full supervision.
Built in tamper sensors trigger an alarm if there is any attempt to tamper
),
with the detector. An automatic testing mode makes testing an ease.
Specifications
,
detection method
power
battery life time
.
installation height
5
coverage
detection speed
start up time
working range
working freguency
,
complies with
environmental class
,
can be operated according to ERC REC 70-03
Hereby, Jablotron Ltd., declares that this JA-60P is in compliance with
the essential requirements and other relevant provisions of Directive
1999/5/EC.
Original of the conformity assessment can be found at the web page
www.jablotron.cz, section Technical support.
Installation
Using the provided bracket, the JA-60P detector can be installed on the
12
[m]
wall or in a corner. The recommended installation height is from 2 to 2.5
,
meters above the floor. The detector covers a distance of up to 12 meters and
(
it has a detection angle of 120°. Do not place the detector close to any
heating/cooling vents or near any other object that often changes
5
,
temperature. The JA-60P should not be placed near any item that generates a
strong electromagnetic signal (transmitters, electronic regulators etc.). Avoid
locations that have intense air circulation.
A. Attach the bracket with the two provided screws, being sure that the
.
arrow inside the bracket is pointing up. We recommend to install one
screw in the pre-cut hole on the lever of the tampering sensor. The
second hole can be easily punched out from the preformed holes.
Tighten the screws firmly, being sure that the bracket is not crooked.
B. Click on the complete detector (including cover). Both tabs must click.
Check that the detector is fixed firmly.
5
.
C. Open the cover of the detector (press in on both sides of the front cover
1/3 from the top)
5
Select Instant or Delayed reaction of the system to the detector's trig-
gering by using DIP switch #2
5
1
,
DIP switches in the detectors
#1 rate of digital signal analysis
,
OFF – standard rate of analysis, fast reaction and good immunity
ON – higher rate of immunity, slower reaction. This setting is suitable for
problematic locations with temperature
changes
or
interference.
#2 reaction of the system to the detector's
.
triggering:
OFF – system will provide an exit
and entrance delay
ON – it will trigger an instant
reaction.
)
(
(
).
.
5
JA-60P WIRELESS P.I.R. MOTION DETECTOR
MDR52402
JA-60P
JA-60P Wireless P.I.R. Motion DETECTOR
Enrollment of the detector to the system
Study the installation manual of the receiver unit (control panel) to learn how to
enter the enrolling mode to enroll the detector. Install the two provided AAA
batteries into the detector (polarity is marked in the detector) and leave it
uncovered. The detector will generate an enrollment signal after the batteries are
installed. The LED in the detector will remain on for about 60 seconds, indicating
that it is in its warm up mode.
Detector testing
Attach the detector's cover and wait until the LED goes out. From this moment
dual PIR sensor with digital processing
the detector will be in a testing mode for 5 minutes and each detected movement
3 V - 2 x AAA battery 1.5V
will be indicated by detector's LED.
about 1 year
Confirm that the detector covers the protected area as you expected (see
from 2 to 2.5 meters
diagram). If you need another coverage pattern (long corridor, pet zone), you can
12m / 120° (with basic lens)
get an optional detector lens from your distributor.
from 0,1 m/s to 4 m/s
Five minutes after the cover was closed, the detector will automatically enter the
60 seconds
normal mode and its LED indicator will be switched off (battery energy saving).
max. 100 m (open area)
Open and close the detector's cover to reset the testing mode for an additional 5
433,92 MHz
minutes if needed.
EN 50131-1 grade 2
II indoor general, -10 to +40°C
Normal operating mode of the detector
The motion detector in normal operating mode conserves battery energy. It will
not indicate triggering with its LED. It will also block the movement sensor for a
period of 5 minutes after a movement is detected. This means that when users are
in the protected area and they move frequently in front of the detector, it will
transmit information about the movement only once every 5 minutes. But when the
users leave the area, the detector will be ready for instant detection 5 minutes after
the last triggering. This system significantly prolongs the life time of the batteries.
To change the period, for which the sensor is blocked after triggering from
5 min. to 1 min., press and hold the detector's tamper switch when you install the
batteries into it. This mode is suitable when you prefer more frequent transmission
of the signal. However, the lifetime of the batteries is usually shorter, depending on
how frequently the detector is triggered.
Note: the detector is ready to send signal about tampering anytime
Battery testing and replacement
The detector automatically checks the condition of its batteries. If it is necessary
to replace the batteries, the detector will inform the system about the need of new
batteries. In this mode the detector works as normal, but each triggering is
indicated with a flash of its LED. This way is possible to recognize, that the
replacement of the batteries is requested. If a low battery is indicated, it should be
replaced as soon as possible (in a week).
Before replacing the batteries, the receiver (control panel) must be put into the
mode, which allows opening of the detectors (User mode or Programming mode).
Use only high quality alkaline AAA batteries for replacement. After installation of
the new batteries the LED will light for about 60 seconds (self testing).
electromagnetic
Attach the detector's cover and wait until the LED goes out. From this moment
analysis
the detector will be in the testing mode and each detected movement will be
standard
higher
indicated by detector's LED. Five minutes after the cover was closed, the detector
will enter the normal mode and its LED indicator will be switched off (battery
energy saving function).
Note: Dispose of batteries safely depending on the type of the batteries and
delay
instant
local regulation. Although this product does not contain any harmful materials we
reaction
suggest you to return the product to the dealer or directly to the producer after
usage.
A
B
rear tamper
lever
attach
click
2 / 2
- 1 -
height
[m]
2,5
2
zone C
zone B
1,5
zone A
1
zone A
0,5
zone C
zone B
1,6
3,7
range
120
12
º
[m]
C
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic
tel.: 420-483-559999
fax: 420-483-559993
open
www.jablotron.cz
MDR51207
MDR52402