Installing Procedures

Wire and Cable Connection

Wire and Cable Connection

Power cord and Ethernet

1.
Connect Power cord (DC12V) with 2-Pin
Terminal block and Cord End Terminal.
2. Connect Ethernet. (RJ-45 Connector).
GPIO & Relay Control
For more information regarding to DI/DO
applications, please read P.7-10(IO Application)
for reference.
IO Connection:
1. DI1 (Digital Input port 1) :DI1 is used for
detecting whether the door is closed or not.
2. DI2 (Digital Input port 2) :DI2 is used to
connect to indoor "Open Door" button. (Or,
it is used for PIR.)
3. DO1 (Digital Output port 1) :DO1 is used
for external lighting.
4. DO2 (Digital Output port 2) :(Reserved)
5. CTRL 1:Connect to CTRL 1 on Relay Board
to control Electronic Door Lock.
6. (-) (GND) :Connect to GND