Comelit 1256 Manual técnico - Página 5
Procurar online ou descarregar pdf Manual técnico para Unidade de controlo Comelit 1256. Comelit 1256 8 páginas. Actuator relay module
Também para Comelit 1256: Manual técnico (16 páginas)

Operation and Programming
Art. 1256 offers the following six functions, depending on the position of jumper JP1:
A) Call repetition function
JP1 as illustrated in Fig. 1
JP3
1
JP1
FIG. 1
The relay is operated by closing the C.NO. contact in response to a call from the switchboard, external unit or landing; this
happens only if the user code for which you wish to repeat the call is set using the DIP-switch (e.g. to activate lights, ringtones,
paging function, CCTV alarm contacts, etc.). On receipt of a call from the external unit or the landing, single closure of the relay
takes place. In response to a call from the switchboard, the relay closes twice. Intercom calls are not repeated. The actuator
relay module can also be used alone, if you want to close the C.NO. contact rather than repeat the call to an apartment when
JP1
the external unit calls the user code set on art. 1256. The relay closure time is set to approximately 2 sec. To set the user code
by means of a DIP-switch, see
B) Activation function on switchboard call pushbutton
JP3
JP1 as illustrated in Fig. 2
1
JP1
JP1
FIG. 2
JP1
For use only with systems not equipped with switchboard art. 1998/A. The relay is operated by closing the C.NO. contact in response
to a switchboard call from an entry phone or video entry phone (e.g. to activate the following independently, using a specific
command: lights, CCTV alarm contacts, driveway gates, entrances without external units or other devices). The relay closure time can
be programmed using a DIP-switch (see
JP1
C) External unit light function / Stair light function
JP1 as illustrated in Fig. 3
JP1
JP1
FIG. 3
The relay is operated by closing the C.NO. contact in response to a call from an external unit to any address, on internal
ignition from a video entry phone (e.g. to automatically activate lights, CCTV alarm contacts, etc.). The relay closure time can
JP1
be programmed using a DIP-switch (see
D) Secondary door lock release function (without external unit)
JP1
JP1 as illustrated in Fig. 4
JP1
FIG. 4
The relay is activated when the door lock release pushbutton is pressed, if the user code of the entry phone or video entry
phone from which the command is sent is within the range defined using DIP-switches - see
door lock release using the door lock release command for entrances without an external unit). The relay closure time is set to
approximately 2 sec.
JP1
JP3
2
1
2
JP2
1
"addressing
table".
table
A). The function can be used only when the system is free.
table
A).
JP1
JP1
JP1
JP1
JP1
JP1
table B
(e.g. to activate a second
5