User Manual – AS5048-AB

2.2 Mounting the AS5048 adapter board

A diametric magnet must be placed over on under the AS5048 position sensor, and should be
centered on the middle of the package with a tolerance of 0.5mm.
The airgap between the magnet and the encoder casing should be maintained in the range
0.5mm~2mm. The magnet holder must not be ferromagnetic. Materials as brass, copper, aluminum,
stainless steel are the best choices to make this part.
Figure 3:
AS5048 – AB - mounting and dimension
2.5mm
Ø6mm
P1
Diametral
Magnet
www.ams.com
Magnet
0.5~2mm
AS5048
22mm
AS5048
18mm
Revision 1.2 / 14.01.2014
4x2.6mm
page 4/12