User menu
The paragraphs below explain all the entries and options contained in the menu intended for the end user, which can be accessed by entering a user code followed
by the "Down arrow".
Alarm
Event log
• Event memory
Use this function to consult the event log. See "Consult event log" paragraph in the previous chapter.
• Alarm memory
Use this function to consult the alarm log. See "Consult event log" paragraph in the previous chapter.
Arm menu
• Total arming
Total arming is used when you are leaving the premises. In this arming condition, the whole system is armed and all detectors trigger an
alarm if violated according to their configuration. Note that some devices, such as flooding and smoke detectors, trigger an alarm regardless
of the arming status.
• Disarming
This procedure executes a system disarm command. An audible confirmation tone and the text "Disarmed" confirm that disarming
has taken place.
• Area arming
This procedure is used to configure a custom arming program in which the user can quickly select the arming status
for each area. See page 6.
• Arming programs
This procedure is used to activate alarm scenarios programmed using the SecurHUB Manager configuration software (contact your
installer).
Arm.prog 1 - Arm.prog 16
Zone status
See also "View / edit zone status" paragraph, page 8.
• List all zones
This procedure is used to list all acquired zones.
• Open zones
This procedure is used to list all open zones.
• Byp./Isol. zones
This procedure is used to list all bypassed and/or isolated zones.
• Zones faults
This procedure is used to list all zones in which a fault has been detected.

Quick commands

This section contains a list of commands that can be selected to manually activate some alarms or to carry out some procedures, such as resetting the alarm
memory, stop sirens and more.
24H: This procedure is used to generate a generic alarm and to send the corresponding message as configured by your installer to the relevant recipients.
Fire: This procedure is used to generate a fire alarm and to send the corresponding message as configured by your installer to the relevant recipients.
Panic: This procedure is used to generate a panic alarm and to send the corresponding message as configured by your installer to the relevant recipients.
Medical: This procedure is used to generate a medical alarm and to send the corresponding message as configured by your installer to the relevant recipients.
Rapine: This procedure is used to generate a rapine alarm and to send the corresponding message as configured by your installer to the relevant recipients.
Water: This procedure is used to generate a water alarm and to send the corresponding message as configured by your installer to the relevant recipients.
Extra time: This procedure is used to generate an "extra time" command which will delay subsequent programmed arming of the control panel according to the
configurations implemented by your installer.
Stop alarm: This procedure is used to stop the sirens that sound after an alarm is triggered. This command does not disarm the system.
Reset alarm: This procedure is used to reset the alarm memory of the system. By default the alarm memory also resets after the system is disarmed. Contact
your installer to find out more about options concerning the alarm memory reset procedure.
Stop reporting: This procedure is used to stop all communications in progress after an alarm is triggered.
Reset fire alarm: This procedure is used to execute a fire alarm reset command.
Call service: For future uses.
Test
This menu is used to perform operational tests for some elements.
• Walk test
The walk test is used to check zone functions. See page 7.
• Sirens test
Sirens test is used to make sure the sirens installed are working properly.
1. Select the siren from the list of available options
2. Select one of the two options, ON or OFF, to switch the siren on and off.
Test
Sirens test
Sirens test
Test external siren
External siren
ON
11