4 Operation
Price
Gas: 4.08 /kWh
Electricity: 12.49 /kWh
4.7.3

Using and programming schedules

About schedules
Depending on your system layout and installer configuration,
schedules for multiple controls may be available.
You can:
▪ Select which schedules you currently want to use.
▪ Program your own schedules if the predefined schedules are not
satisfactory. The actions you can program are control specific.
Possible scheduling screens
Name and location
[1.2] Room > Heating
Program the desired room temperature
schedule
in heating mode.
[2.2] Main zone > Heating
Program the desired leaving water
schedule
temperature for the main zone in
heating mode.
[3.2] Additional zone >
Program the desired leaving water
Heating schedule
temperature for the additional zone in
heating mode.
[4.2] Space heating/
See
cooling > Operation mode
mode" on
schedule
[5.5] Tank > Schedule
Program the domestic hot water tank
temperature for your normal domestic
hot water needs:
▪ Comfort setpoint
▪ Eco setpoint
▪ Reheat setpoint
[7.4.2] User settings >
Program when the unit has to use which
Quiet > Schedule
quiet mode level:
▪ Off
▪ Quiet
▪ More quiet
▪ Most quiet
[7.5.4] User settings >
Program when a certain electricity tariff
Electricity price >
is valid.
Schedule
Example of programming a schedule
See
"4.7.4 Schedule screen: Example" on
4.7.4

Schedule screen: Example

This example shows how to set a room temperature schedule in
heating mode for the main zone.
INFORMATION
The procedures to program other schedules are similar.
To program the schedule
Example: You want to program the following schedule:
User defined 1
Mon
Tue
Wed
Thu
Fri
Sat
Sun
User reference guide
12
Value in breadcrumb
[7.6]=8.6
[7.5.1]=17
Usage
"4.4.2 Setting the space operation
page 6.
page 12.
Prerequisite: The room temperature schedule is only available if
room thermostat control is active. If leaving water temperature
control is active, you can program the main zone schedule instead.
1 Go to the schedule.
2 Clear the contents of the schedule (optional).
3 Program the schedule for Monday.
4 Copy the schedule to the other weekdays.
5 Program the schedule for Saturday and copy it to Sunday.
6 Give the schedule a name.
To go to the schedule:
1 Go to [1.1]: Room > Schedule.
2 Set scheduling to Yes.
3 Go to [1.2]: Room > Heating schedule.
To clear the contents of the schedule:
1 Select the name of the current schedule.
User defined 1
Mon
Tue
Wed
Thu
Fri
Sat
Sun
2 Select Delete.
Delete
Edit
3 Select OK to confirm.
To program the schedule for Monday:
1 Select Monday.
User defined 1
Mon
Tue
Wed
Thu
Fri
Sat
Sun
2 Select Edit.
Delete
Edit
Copy
3 Use the left dial to select an entry and edit the entry
with the right dial. You can program up to 6 actions
each day.
Mon
0
12
24
6:00
20°C
22:00
18°C
8:30
18°C
--:--
--
17:30
21°C
4 Confirm the changes.