C. General settings
Choose option 3 from the main menu and the following menu will appear on the
screen.
C A R D I N ACD-148 V. 3102 (1994) Cardin Elettronica S.p.A.
**** GENERAL SETTINGS****
1. CANCEL USER CODE MEMORY
2. CANCEL FORMER EVENTS MEMORY
3. RELAY DELAY
4. OUTPUT ACTIVATION
5. END
ENTER >>>
C1.
Cancel user code memory.
Choosing option 1 from this menu allows you to cancel all the users from (EEP-
ROM) memory.
The following message appears on the screen:
!! CANCEL MEMORY: CANCEL ALL USER CODES !!
ARE YOU SURE? [Y/N] >>
If you answer Y twice all the user information will be cancelled from memory
Throughout this operation (the length of which depends on the amount of memorised
data) the following message will remain on the screen
after which the following message will appear
C2.
Cancel former events memory
Choosing option 1 from this menu allows you to cancel the buffer memory which
contains the last 198 events.
The following message appears on the screen:
!! CANCEL MEMORY: CANCEL FORMER EVENTS MEMORY !!
ARE YOU SURE? [Y/N] >>
If you answer Y the buffer memory will be erased
C3.
Relay delay
28
** D E L E T I N G **
TYPE < ESC > to EXIT
- inserting or modifying user details;
- cancelling the user memory or the events buffer memory;
- modifying the relay drop-out delay time;
- displaying a complete list of the systems user's both enabled and disabled and
the display of information regarding the last transition.
At the back of the appliance there are 4 dip-switches allowing zone partitioning
(see fig.6 page 18) e.g. these can allow programming in specific time bands by
connecting an external timer or signal reception only when the user is located
within the range of a detector.
ELECTRICAL SPECIFICATIONS
- Power supply voltage: ......................................................... 230 V ac / 50 Hz
- Power consumption: .......................................................... 35 mA @ 220 Vac
- Maximum number of memorised user codes: .................... 2000
- Maximum number of events stored in the buffer memory: 198
- Transmitter model: .............................................................. CARDIN - mod. S48
- Number of individual channels: .......................................... 4
- Number of controllable I/O's: .............................................. 4
- Number of inputs which may be enabled: .......................... 4
- Average time lag per enabled TX: ...................................... 225 mS
- N. 4 Relays with resistive load
- Maximum commutable power
- Load in dc ........................................................................... 28W
- Load in ac ........................................................................... 60 VA
- Adjustable drop out delay ................................................... from 500 mS to 4 S.
- Maximum number of random generated codes: ................ 7077888
- Number of combinations per encoded access key: ............ 16384
- 8 character password
- Stand-by battery ................................................................. 2.1 Ah
- Stand-by battery autonomy................................................. 24 hrs
- Hardware watchdog
RADIOFREQUENCY RECEPTION CARD
- reception frequency ............................................................. 27.195 MHz
- local oscillation frequency .................................................... 27.650 MHz
- local oscillation frequency .................................................... 30 p.p.m.
............................................................................................. from -10° to +55°C
- intermediate frequency ........................................................ 455 KHz
- impedance in input .............................................................. 50 Ω
- sensibility (with a finely tuned signal) ................................... 0.5 µV
- local oscillation emission ..................................................... ≤70dBm (<100pW)
RS-232 INTERFACE
- CANNON 9 pole Male connector
5
: GND
3
: TX
2
: RX
- Protocol
: XON / XOFF
- Baud rate
: SELECTION: from 1200 BAUD to 9600 BAUD
- Parity
: NONE
- N Bit
: 8
5