7.1. Command to the ACR100I

7.1.1.

CCID Command Pipe Bulk-OUT Messages

ACR100I shall follow the CCID Bulk-OUT Messages as specified in CCID section 4. In addition, this
specification defines some extended commands for operating additional features. This section lists
the CCID Bulk-OUT messages to be supported by ACR100I.
7.1.1.1.
PC_to_RDR_IccPowerOn
Activate the card slot and return ATR from the card
Offset
0
bMessageType
1
2
5
bPowerSelect
6
7
The response to this message is the RDR_to_PC_DataBlock message and the data returned is the
Answer-To-Reset (ATR) data.
7.1.1.2.
PC_to_RDR_IccPowerOff
Deactivate the card slot.
Offset
0
bMessageType
1
5
6
7
The response to this message is the RDR_to_PC_SlotStatus message.
7.1.1.3.
PC_to_RDR_GetSlotStatus
Gets the current status of the slot.
Offset
0
bMessageType
1
5
6
ACR100I – Reference Manual
Version 1.00
Field
Size
1
dwLength
4
00000000h
bSlot
1
bSeq
1
1
abRFU
2
Field
Size
1
dwLength
4
00000000h
bSlot
1
bSeq
1
abRFU
3
Field
Size
1
dwLength
4
00000000h
bSlot
1
bSeq
1
Value
Description
62h
Size of extra bytes of this message
Identifies the slot number for this
command
Sequence number for command
Voltage that is applied to the ICC
00h – Automatic Voltage Selection
01h – 5 volts
02h – 3 volts
Reserved for future use
Value
Description
63h
Size of extra bytes of this message
Identifies the slot number for this
command
Sequence number for command
Reserved for future use
Value
Description
65h
Size of extra bytes of this message
Identifies the slot number for this
command
Sequence number for command