Bosch sce53m05au Manual de Instruções - Página 19
Procurar online ou descarregar pdf Manual de Instruções para Máquina de lavar loiça Bosch sce53m05au. Bosch sce53m05au 23 páginas. Bosch dishwasher operating instructions
– After installing the appliance, ensure
that the plug is easily accessible.
– Some models:
The plastic housing on the water
connection contains an electric valve,
the connecting cables are in the supply
hose. Do not cut through this hose,
do not immerse the plastic housing in
water.
Delivery
Your dishwasher has been checked
thoroughly in the factory to ensure that it is
in working order. This may cause small
water stains. These will disappear after the
first wash cycle.
Technical specifications
Weight:
max. 24 kg
Voltage:
220–240 V, 50 Hz or 60 Hz
Connected load:
2.0–2.4 kW
Fuse:
10/16 A
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing valve
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
for cold water connection only.
Installation
The required installation dimensions can
be found in the installation instructions.
Level the appliance. Ensure that the
appliance is situated securely on the floor.
– The appliance can easily be
installed in a fitted kitchen between
wooden and plastic walls.
Waste-water connection
– The required work sequence can be
found in the installation instructions. If
required, fit a siphon with an drainage
connection.
– Connect the waste-water hose to the
drainage connection of the siphon with
the enclosed parts.
Ensure that the drainage hose is not
kinked, crushed or twisted and that
there is no cover plate in the drainage
to prevent the waste water from flowing
out!
Fresh water connection
– Connect the fresh-water connection to
the tap according to the installation
instructions with the enclosed parts.
Ensure that the fresh-water connection
is not kinked, crushed or twisted.
– When replacing the appliance, always
use a new water supply hose.
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing valve
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
for cold water connection only.
Electrical connection
– Connect the appliance to an
alternating current only, ranging from
220 V to 240 V and 50 Hz or 60 Hz
via a correctly installed socket with
protective earth conductor. See rating
plate for required fusing 1Z.
– The socket must be near the appliance
and freely accessible following
installation.
If the plug is not freely accessible, an
allpole disconnector with a contact
opening of at least 3 mm must be
fitted on the installation side to satisfy
the relevant safety instructions.
en
19