REFRIGERATOR COMPARTMENT (A)
The air is pushed by the fan down the foam duct at the bottom of the compartment: it enters by nozzle 1 and
comes out of nozzle 2. Manual flap C enables to regulate the flow of cold air and therefore the temperature
inside the compartment.
The thermostat bulb is located inside the flap and reacts both to the air temperature of the air coming out of
nozzle 2, and to the air temperature inside the refrigerator compartment.
The air returns to the air compartment through the foam duct at the bottom of the compartment, entering from
nozzle 3 and leaving from nozzle 4.
FREEZER COMPARTMENT (B)
The cold air is pushed into the compartment by the fan through the two nozzles 5 and 6. After circulating, the air
is rechannelled to the evaporator battery through opening 7, under the protection panel.