All health and safety procedures and recommendations must be followed as detailed in the Horizon Compact + User Manual.
This product is to be installed and maintained by experienced telecommunications personnel only. Installations must adhere to specifications listed in the Horizon Compact+ User Manual.
Horizon Compact+ is to be installed with proper grounding, Horizon PonE surge arrestor and 48 v power connected through the Horizon PonE according to instructions in the Horizon Compact+ User Manual
Mechanical
Radio/Modem (no antenna)
10.2 cm x 24.3 cm x 22.1 cm; 3.4 kg / 4 in x 9.6 in x 8.7 in; 7.5 lbs
Power, Connections, Payload
Operating Temperature
-40°C to + 50°C (-40°F to +122° F)
With Heat Shield
-40°C to + 60°C (-40°F to +140° F)
Humidity
100 % Condensing
Input
-40.5 VDC to -56 VDC (-48 VDC nominal), 110/240 VAC (Opt.)
Consumption (per link end)
43 - 80 Watts depending on RF frequency
Power
-48V, PonE, or Direct DC
Payload (+ Inband NMS)
Shielded RJ45 or optical LC, 1000/100/10 BaseT
Interface
2x10/100/1000bT, or 4x10/100bT, or 1x10/100/1000bT plus 2x
<200μs, Typical 120μs GigE
Latency GigE
Base Capacity
Variable: 10 to 800 Mbps full duplex CIR
Frame Size
64 to 9600 Bytes
Flow Control
Yes
Prioritization
8 levels with 8 queues ; 802.1p/q, MPLS, DSCP ToS Bits
Modulation Shifting
Yes, Hitless
Network Management (NMS)
SNMP
SNMP Traps, Enterprise MIB, SNMP v1, v2c and v3
EMS
DragonVision, SSL, HTTP,SSH, Radius
LLDP
Supported by DragonVision Element Manager
Channel BW, Throughput, Tx Power, Rx Sensitivity
The table below shows examples for two18 GHz Radio Bands.
18 GHz FCC/IC Radio Band
Bandwidth
Modulation
Throughput
Tx Power
QPSK PTCM2
66
23.7
64QAM PTCM2
241
20.0
50 MHz
256QAM PTCM2
329
19.5
256QAM 1
351
19.5
QPSK PTCM2
52
23.7
64QAM PTCM2
192
20.0
256QAM PTCM2
262
19.5
256QAM 1
279
19.5
40 MHz
QPSK PTCM2
39
23.7
64QAM PTCM2
144
20.0
256QAM PTCM2
196
19.5
256QAM 1
209
19.5
QPSK PTCM2
26
23.7
64QAM PTCM2
94
20.0
20 MHz
256QAM PTCM2
129
19.5
256QAM 1
137
19.5
QPSK PTCM2
12
23.7
64QAM PTCM2
44
20.0
10 MHz
256QAM PTCM2
60
19.5
256QAM 1
64
19.5
18 GHz ETSI/ITU Radio Band
QPSK PTCM2
71
23.7
64QAM PTCM2
261
20.0
55/56 MHz
256QAM PTCM2
356
19.5
256QAM 1
380
19.5
QPSK PTCM2
38
23.7
28/27.5
64QAM PTCM2
138
20.0
MHz
256QAM PTCM2
188
19.5
256QAM 1
201
19.5
QPSK PTCM2
19
23.7
14/13.75
64QAM PTCM2
68
20.0
MHz
256QAM PTCM2
93
19.5
256QAM 1
99
19.5
QPSK PTCM2
9
23.7
64QAM PTCM2
34
20.0
7 MHz
256QAM PTCM2
47
19.5
256QAM 1
50
19.5
Customer Support International Help Desk: +1 613 271 7010 email:
Installation Requirements
Installation kits include the following:
Cables
10/100bT
Rx Sensitivity
Rx Saturation
-83.2
-13.1
-69.4
-20.0
-53.4
-23.0
-61.0
-24.3
-84.2
-13.1
-70.4
-20.0
-64.4
-23.0
-62.0
-24.3
-85.5
-13.1
-71.7
-20.0
-65.7
-23.0
-63.2
-24.3
-87.3
-13.1
Grounding, Power and Lightning Protection
-73.5
-20.0
-67.5
-23.0
-65.0
-24.3
Device must be effectively
-90.6
-13.1
-76.8
-20.0
grounded / earthed in order to
-70.8
-23.0
protect against lightning strikes
-68.4
-24.3
-82.9
-13.1
loops and sharp bends.
-69.1
-20.0
-63.1
-23.0
When configured with a copper interface, power and network connections are fed to the Horizon via a
-60.6
-24.3
proprietary Power-on-Ethernet (PonE) power injector and surge arrestor
-85.7
-13.1
-71.9
-20.0
-65.9
-23.0
-63.4
-24.3
The Power Injector/Surge Arrestor MUST be mounted as close as possible to,
-88.7
-13.1
and above, the building entry point (BEP) and its external grounding lug must be
-74.9
-20.0
-68.9
-23.0
connected to the nearest lightning (LPS) ground with #6 AWG (minimum)
-66.5
-24.3
grounding wire, avoiding loops and sharp bends.
-91.7
-13.1
DO NOT connect the grounding lug to AC power supply wiring ground!
-77.9
-20.0
DO NOT mix AC power supply option with site-supplied 48 VDC!
-71.9
-23.0
DO NOT connect the network to the RJ-45 connectors marked
-69.5
-24.3
"TO HORIZON UNPROTECTED". Damage to switches or routers may result
web:
2 x PonE power/surge units
2 x Grounding Kits with cable and bolts
AC option – 2 x AC/DC power converter and cables
AC/DC Option – 1 x AC power adapter
2 x weather caps for unused physical port
2 x Ethernet cable splitter/combiner
Shielded, outdoor rating, Cat5E cables are
required on the unprotected side (to Horizon).
Recommended cable: Belden 7919A. Shield
must be connected to metal shell of RJ45
connectors at both ends of cable!
Unshielded
Cat5E
cables
connectors are required on protected side of
PonE unit (to Network). Cat5E cables may be
supplied by the customer, or ordered from
DragonWave.
Power cable: 2-wire 16 AWG
Mounting Masts and Twist &
Sway
Minimim 2 3/8" OD thick walled (SKD-80) mast
for 30 cm and 60 cm antennas.
Minimum 3" OD thick walled mast for 90 cm
and 120 cm.
Minimum 4" OD thick walled mast for 180 cm.
Maximum angular twist is ½ of the beamwidth.
There is one grounding point available on the
Horizon Compact casing (see diagram under
"Ports"). Use 6 AWG wire (minimum) to
connect the casing to lightning protection
and surges
system
(LPS)
grounding
structure ground. Use shortest length, avoiding
DragonWave Inc.
http://support.dragonwaveinc.com
The power injector supports redundant -48 V DC power feeds and protects the power supply
and network from power transients created by lightning or other sources.
Ports
and/or
RJ45
Port 1 and Port 2 may be configured as two 100/10 Base-t (Fast Ethernet) ports, or as single
1000/100/10 Base-t (Gigabit) ports. Any of the 4 possible ports may be configured for in-band or
out-of-band management. Power is fed to Port 1 for copper interface or Port 2 for fibre interface.
BNC Field strength monitoring port is for alignment purposes.. Also used for redundancy switching
applications.