Electrolux 527 series Manual - Página 3

Procurar online ou descarregar pdf Manual para Máquina de lavar roupa Electrolux 527 series. Electrolux 527 series 24 páginas.

Electrolux 527 series Manual

Demo Mode:

The Demo works in two ways: Interactive Mode and Automatic Loop.
The Interactive Mode enables the customer to use the interface
without activating the appliance. The machine behavior appears similar
to normal operation. With the door closed, pressing start, the appliance
turns on and the display counts down by the second from the maximum
time displayed with its respective cycle. The appliance turns off when it
reaches "
".
The Automatic Loop will engage if no one interacts with the user inter-
face for 3 minutes, or the start button hasn't been pressed. The machine
will simulate a cycle execution on the display only.
Entering Demo Mode:
1 Press power and look for console light up.
2 For Rotary Dial Cycle Select Washer: Within 10 seconds select
fast wash and then simultaneously press and hold temp and select
(set) buttons for 3 secs. Skip to Step 4.
3 For Push Button Cycle Select Washer: Within 10 seconds select
rinse & spin and then simultaneously press and hold temp and
select (set) buttons for 3 secs. Continue to Step 4.
4 The message "
" will blink 3 times in the center display.
5 If "
" message does not appear, turn off machine and repeat
previous steps.
NOTE
Once Demo Mode is activated, every time the machine is turned on,
Demo Mode is automatically recalled; this occurrence is signaled at
the start-up by the text "
Unplugging the unit will not clear Demo Mode. See "Exiting Demo
Mode" for more information.

Washer Error Codes

Error
Error Description
Code
11
Fill time too long
13
Water leak in tub or in pressure sensor
21
Water not pumping out fast enough
23
Drain triac error
24
Drain triac error sensing
31
Electronic pressure switch error
32
Pressure sensor calibration problem
35
Pressure sensor indicates water overfill
38
Air trap clogged
41
Control board thinks the door switch is open
42
Door lock device failure
43
Door lock triac failure
44
Door closed sensing failure
45
Line door sensing failure
55
Motor under speed
(select models)
(not available on 300 series)
57
High current on inverter (motor control)
58
High current on motor phase
59
No spin signal for 3 seconds
5A
High temperature on control due to overload (motor control)
5B
Motor control under voltage
Demo Mode/Washer Error Codes
" flashing 3 times in the center display.
Exiting Demo Mode:
To exit Demo Mode, perform the same sequence used to enter Demo
Mode.
1 Press cycles to advance the cycle selection to Delicates.
2 Press start; then Press cancel.
3 Press power to turn the unit off.
4 Press power to turn the unit on. The unit will display will flash "
3 times on the numeric display.
5 Press and hold temp and select (set) simultaneously. The appliance
will beep once, the numeric display will cycle off and on. The appli-
ance will then beep with the normal power on sequence.
You may also perform a Factory Default Reset - see below.

Factory Default Reset:

1 Press power and look for console light up.
2 Wait at least 10 seconds, then simultaneously press and hold soil
and options buttons for 3 secs.
To return to factory settings,
press the soil and options buttons at
the same time and hold until the signal
sounds.

Recalling Last Error Code:

1 Press power and look for console light up.
2 Wait at least 10 seconds, then simultaneously press and hold temp
and select (set) buttons for 3 secs.
3 The display will show the last error in memory.
4 Clear the display and return to normal operation by touching any
button or by pressing the power button.
Display
Next Step
Notification
Yes
Refer to test (1)
No
Refer to test (2)
Yes
Refer to test (3)
No
Refer to test (3)
No
Refer to test (3)
No
Refer to test (4)
No
Refer to test (4)
No
Refer to test (5)
No
Refer to test (5)
Yes
Refer to test (6)
No
Refer to test (6)
No
Refer to test (6)
No
Refer to test (6)
No
Refer to test (6)
No
Check for heavy or unbalanced load
Refer to test (9)
No
Refer to test (8)
No
Refer to test (8)
No
Refer to test (9)
No
Refer to test (8)
No
Check supply under load and wiring to unit
Refer to tests (6 and 9)
3
"