Problem
The appliance is not producing steam
properly
Error message
appears in the dis-
"‹‚‚
play
An
... error message appears in the dis-
"
play
The appliance is not heating The colon
flashes in the display

Replacing the cooking compartment bulb

Heat-resistant 230 V/25 W halogen bulbs with seals are
available from the after-sales service. Please specify the E
number and FD number of your appliance.
ã=
Risk of burns!
Allow the cooking compartment and cooking compartment light
to cool before changing the bulb.
Always use a dry cloth to remove a new halogen bulb from the
packaging, otherwise it will not last as long.
Switch off the fuse in the fuse box or unplug at the mains.
1.
Turn the cover anti-clockwise to remove.
2.
Remove the bulb and replace with a bulb of the same type.
3.
Slide the new seals and the clamping ring onto the glass
4.
cover in the right order.
Screw the glass cover with the seals back on again.
5.
Connect the appliance to the mains and reset the clock.
6.
Never operate the appliance without the glass cover and seals.
Replacing the glass cover or seals
Any damaged glass cover or seals must be replaced. Please
provide the after-sales service with the E number and FD
number of your appliance.
Possible cause
Limescale has formed in the appliance
A button was pressed for too long or is
jammed
Technical fault
A button combination was actuated

Changing the door seal

If the seal around the outside of the cooking compartment is
faulty, it must be replaced. Replacement seals for your
appliance can be obtained from the after-sales service. Please
specify the E number and FD number of your appliance.
Open the appliance door.
1.
Pull off the old seal.
2.
Push in the new door seal at one point and pull it in all the
3.
way round. The joint must be at the side.
Check again that the seal is correctly fitted in the corners.
4.
Notes/remedy
Start the descaling programme.
Press the
button to clear the fault mes-
0
sage. Press all of the buttons individually
and check if they are clean
Press the
button to delete the error
0
message. Reset the clock if required. If the
error message appears again, call the
after-sales service
Set the Steam operating mode to 35 °C,
then press and hold the
D
audible signal sounds. Press the
ton again briefly
button until an
but-
D
19