Wipe the outer surfaces of the flow heater and the combination faucet with a soft clout damped
in a detergent solution. Do not use aggressive solutions or rough cleaning agents! Let an expert deal with
larger maintenance and repairs!

2.4 GRAPH OF WATER HEATING

Temperature of heated water
The graph shows dependence of maximum water flow A [l/min.] on the temperature outflowing water
B [°C] for the 3.5 kW and 5 kW power inputs. The data apply even if the temperature of the inflowing water
is 10°C.
Example: From a 0733 (3.5 kW) type heater, water of 50°C temperature will outflow at the temperature
of inflowing water 10 °C and flow of 1.2 l/min.
Temperature of heated water
The graph shows dependence of maximum water flow A [l/min.] on the temperature outflowing water
B [°C] for the 6.5 kW and 8 kW power inputs. The data apply even if the temperature of the inflowing water
is 10°C.
Example: From a 2733 (6.5 kW) type heater, water of 50°C temperature will outflow at the temperature
of inflowing water 10 °C and flow of 2.5 l/min.