Drazice AIR 2,6 kW Manual de operação e instalação - Página 15
Procurar online ou descarregar pdf Manual de operação e instalação para Ar condicionado Drazice AIR 2,6 kW. Drazice AIR 2,6 kW 19 páginas. Outdoor unit
Location for Installing Outdoor Unit
Where it is convenient to install and well ventilated. Avoid installing it where flammable gas could leak.
Keep the required distance apart from the wall.
The distance between Indoor and outdoor unit should be 5 meters and can go up to maximum 15 meters
with additional refrigerant charge.
Keep the outdoor unit away from greasy dirt, vulcanization gas exit. Avoid installing it by the roadside
where there is a risk of muddy water. A fixed base where it is not subject to increased operation noise.
Where there is not any blockage of the air outlet.
Avoid installing under direct sunlight, in an aisle or sideway, or near heat sources and ventilation fans.
Keep away from flammable materials, thick oil fog, and wet or uneven places.
Indoor unit
Max. Allowable Tubing
Model
Length at Shipment (m)
2,1k~5,3kW
7kW
If the height or pipe length is out of the scope of the table, please consult the merchant.
Pipe length is
15 meters Max.
Outdoor unit
Limit of Tubing
Length (m)
5
5
Pipe length is
15 meters Max.
Indoor unit
Limit of Elevation
Difference H (m)
15
5
15
5
- 15 -
Outdoor unit
Required amount of
additional refrigerant (g/m)
20
30