Carlon 150MRS Manual de início rápido - Página 2

Procurar online ou descarregar pdf Manual de início rápido para Instrumentos de medição Carlon 150MRS. Carlon 150MRS 2 páginas. Industrial meters
Também para Carlon 150MRS: Manual de iniciação rápida (2 páginas)

Carlon 150MRS Manual de início rápido
METER X PIPE
MODEL
SIZE
5/8 X1/2" thd
625MRS
5/8 X 3/4" thd
6251MRS
3/4" thd
750MRS
1" thd
1000MRS
1 1/2" thd
150MRS
2" thd
200MRS
*The size of meter selected should be based upon continuous flow, GPM, as opposed to pipe size. For example,
if it is determined that continuous flow is 25 GPM, a 1"meter should be selected rather than a 3/4" meter.
ORDERING INFORMATION: Specify model number shown followed by choice of contact pulse settings desired.
Add a G for gallon reading or a C for cubic feet reading (call factory for other register reading abbreviations).
Example: 1 1/2" meter with gallon register and 10 gallons per contact = 150MRS-10 GPC.
METER X PIPE
SIZE
5/8 X1/2" thd
5/8 X 3/4" thd
3/4" thd
1" thd
1 1/2" thd
2" thd
Meter Connection: Carlon supplies connections with all MRS meter orders.
Pressure rating: Do not exceed 150 psi.
PH Level Range: 6.5 - 8.0
Temperature Range: Protect the meter from freezing and within the temperatures of 35 to120 ° F.
Accuracy: +/- 1.5% of maximum flow when operating between minimum and maximum flow range
Register Options: U.S. Gallons, cubic feet, metric.
Installation Instructions:
1. Flush the line thoroughly after all plumbing changes to prevent contaminates from entering the meter.
2. Install horizontally with the register facing up and inlet port facing the water supply line.
3. Dry contact type, reed switch meters with maximum switching voltage of 48 V AC/DC, maximum
current .2 amps, 3 watts.
4. If an outdoor installation, meter must be protected from the elements.
Warranty: Carlon warrants its products to be free of defect in material or workmanship for a period of
twelve months from the date of purchase. Contact us to obtain a copy of our complete statement of
warranty.
Helpful Hints:
1. Install a Carlon Slow-Closing Valve downstream of your water meter.
This will eliminate possible meter damage from water hammer in your system.
2. Install a Carlon Strainer upstream of your water meter to protect the meter and any
other in-line process equipment from becoming jammed by particulate matter in your system.
Additional Information: If you require additional information, visit us online at www.carlonmeter.com
METER SELECTION CHART
*CONTINUOUS
FLOW
FLOW
RANGE
8 GPM
1/4 - 20 GPM
10 GPM
1/4 - 20 GPM
15 GPM
1/2 - 30 GPM
25 GPM
3/4 - 50 GPM
50 GPM
1 1/2-100 GPM
65 GPM
2 - 130 GPM
X = AVAILABLE CONTACT SETTINGS
(All pre-set at the factory to your specifications)
MODEL
625MRS
6251MRS
750MRS
1000MRS
150MRS
200MRS
MRS METER SPECIFICATIONS
WEIGHT
LENGTH
3.3 lbs.
7 1/2
3.3 lbs.
7 1/2
3.7 lbs.
7 1/2
5.7 lbs.
10 3/4
10.6 lbs.
12 5/8
22 lbs.
15 1/4
0.1 GPC
1 GPC
X
X
X
X
X
X
X
X
HEIGHT
WIDTH
4 1/8
3 7/8
4 1/8
3 7/8
4 1/2
4
4 1/2
4
6
5
7
6 1/2
10 GPC
100 GPC
X
X
X
X
X
X
X
X
X
X
X
X
CONNECTION
LENGTH [X2]
2 3/8
2 1/2
2 1/2
2 5/8
2 7/8
3